LCR Meter
LCR meters measure inductive, capacitive and ohmic resistances quickly and with high precision.
The LCR meter and capacitance bridge can be used to measure alternating current resistances and phase angle as well as components' performance. The special resolution of these LCR meters with 6 digits display and the high testing voltage up to 10V allow exact assessments of the capacitance of capacitors and the inductivity of coils. Particularly talked about is the convenient judgement comparator function of this first class capacitance bridge. Check the quality of your devices simply with the GOOD and BAD values. The device can be niftily controlled by a PC or an SPS with the RS232 interface or the fast 24-volt control interface. An LCR meter with this command structure is brilliantly integrable into LabView or into testsystems with existing software. The reliable LCR meter is meant for, in the most part, use in manufacturing and assembly as well as universities and laboratories. The inductance meter from the DU series is at the same time a first class multimeter and applicable as an ESR meter, for example for the measurement of Electrolyte capacitors. Additional multimeters are to be seen in the Sourcetronic measuring technology shop. The LCR measuring tools are unique in their large bright displays which are viewable from all angles and from a distance. All in all a top flight LCR measuring bridge, in a robust case.
+49 421 277 9999
- Accuracy: 0.1%
- Frequency range: 100 Hz - 100 kHz
- Measuring speed: 250ms
- DCR: 0.0000 Ω - 20 MΩ
- Resolution: 4¾ digits
- Display: LCD Dual
- Interfaces: USB
- Extra: ST2822X software, incl. accessories
- Accuracy: 0.1%
- Frequency range: 20 Hz - 5 MHz
- Measuring speed: 5ms
- DCR: 0.00001 Ω - 99.9999 MΩ
- Resolution: 5 digits
- Display: LCD display
- DC bias: ±5 V
- Interfaces: USB, LAN-LXI, RS232C, Handler, optional: GPIB
- Extra: Test level 5V, 4 x output impedances, trace sweep, incl. accessories
- Plug & Play Ansteuerung für Sourcetronic LCR Messgeräte
- Komplette Fernsteuerung der Messgeräte
- Komfortable Oberfläche im JAVA "look&feel"
- Automatisch skalierende graphische Kurven-Verläufe
- Linear & logarithmisch
- Extra "Live"-Daten Fenster
- Automatische Nullkalibrierung Short / Open
- Spezialfunktion "Frequency Sweep in graphischer Darstellung
- Benutzerdefinierbarer Grenzwertvergleich
- Comfortable measurement software with special functions
- "Frequency Sweep" / "Analyzer Function"
- Data display, data logging, analysis, report
- Runtime chart, e.g. cooling curves
- Language: English / German
- Communication via RS-232 and USB
- Export file: CSV, Excel
- Application upgrade in order to your requirements
- Frequency up to 300kHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagnetic parts
- Can be used with commercial LCR bridges
- Frequency up to 5MHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagentic parts
- Can be used with commercial LCR bridges
- Frequency up to 300kHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- Cable length: 0.8 m
- distance between the BNC sockets: 22mm
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagnetic parts
- Can be used with commercial LCR bridges
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters
- 2-Wire-Test-Leads
- High quality BNC plugs
- Alligator style clips (red / black)
- BNC cable contact
- High quality BNC connectors
- LCR meter / DC bias source
- Approximately 50cm long
- Device: ST2822
- 4-wire-measurment
- Kelvin test leads with terminal
- Cables color coded
- Contacts gold plated
- SMD Tweezers with BNC
- High qulaity BNC connectors
- Measuring leads gold plated
- Terminal for LCR bridges
and measuring equipment, multimeter
Sourcetronic LCR Meter - Zero calibration
With an LCR meter it is feasible to determine the impedances, which means the complex resistances of two-terminal components. LCR measuring devices are able to measure current, voltage and phase shift and calculate from that the LCR values, which can be represented in all possible forms (e.g. Z, R and X, series equivalent circuit Ls, Cs and Rs or parallel equivalent circuit Lp, Cp and Rp, etc.). There are portable handheld LCR measuring devices which are usually easy to use and there are also table and laboratory LCR meters in various sizes and ranges from 1 kHz to 100 MHz and even beyond.
How do I determine the correct LCR measuring device for my requirements?
In addition to the measuring ranges to be determined, the frequency range must be specified in each case, which is decisive for the price of the devices. Ordinarily the test specimens should be measured with the frequency with which they are operated later. Moreover, a LCR bridge often has very helpful functions, e.g. the comparator function, or the list-sweep-function. In the comparator mode, you can enter threshold values for the test specimens and the measuring device automatically evaluates to "GOOD" or "BAD" and can control a sorter with several compartments. The list-sweep function offers the possibility to automatically test a specimen with different frequencies, similar to an impedance analyzer, with the extraordinary well-equipped ST2829 series even with graphical frequency response over up to 801 frequency points. All in all, a LCR meter is suitable for direct and precise measurements of inductors, capacitors and resistors under different test frequencies. At the same time the test range can be selected manually or automatically. The LCR meter can also be operated fully automatically, e.g. via the interfaces RS-232, USB, GPIB, LAN or Handler. With specialized control software like our own ST© Meter, the measurements can be logged and evaluated accordingly.