Drive Technology
Brake Resistors
Aluminium Brake Resistor
Brake unit DBU
High Protection Resistor SHPA
Control Cabinet
EMI Filter
Input Filter 690V
Input Filter IP20
Frequency Inverter
Accessories
Rental Frequency Inverter
Software
ST130
ST150 230V
ST150 400V
ST500 230V
ST500 400V
ST500 500V
ST500 690V
ST600 400V
ST600 400V IP55
Motor Controls
Accessories
Pump controls
SPC-G3
Reactors
Motor reactor
Line reactor
Sine Wave Filter
Measurement Technology
Battery tester
Calibration Services
Capacitance Meter
DC Bias Current Source
Accessories
Digital Power Meter
Ground Bond Tester
Accessories
High Voltage Relays
Hipot tester
Accessories
High Voltage Cables
Safety Workplace
ST9200
Test Cage
Test Dummy
UB36
UG36
UH28C
UH36
UX36
HV Probe
Impedance Analyzer
Insulation Tester
ST2683
ST2684
LCR Meter
LCR Meter Accessories
Software
ST2822
ST2826
ST2827
ST2829
ST2830
ST2838
ST2839
Measurement Software
Milliohmmeter
Accessories
ST2515
ST2516
Multimeter
Accessories
Bluetooth Multimeter
Digital Multimeter
ST1940
ST1950
Relay Matrix
Rental Equipment
Safety Tester
Accessories
Profitest
Secutest
ST400
Surge Tester
Accessories
ST2883
Test Systems
Transformer Tester
Accessories
ST2829X
Transport Cases
Cases
Trolleys
Measurement ENERGY
Earth Tester
EM-4058
TM25R
Megohmmeter
MD 5060
MD-10/15kV
MI 2000
Microohmmeter
10A
1A
200A
Accessories
Top Seller
Demo Devices For Sale
FAQ
Glossary
Contact
Blog
Jobs
Company
Contact
Go to homepage
+49 421 277 99 99
My account
Login
or sign up
0
Show all categories Line reactor Back
  • Show Line reactor
  1. Home
  2. /
  3. Drive Technology
  4. /
  5. Reactors
  6. /
  7. Line reactor
  • Reactors
    • Line reactor
    • Motor reactor
Filter
–
Zertifiziert nach ISO 9001:2015
ISO_9001_sw_single

Line reactor

Input chokes are coils with low, ohmic resistance, which reduces high frequency input currents at a grid connection effectively. These high performance AC input chokes are characterised by a high linearity and a strong reduction of the overtone. They are suitable for the connection to the 3-phase 400 V grid and  available in different power classes matching the Sourcetronic frequency inverter classes. Inchoate with the AC input choke SCI-0005-E2M8C with a power of up to 1,5kW and a current pending 5A, up to the AC input choke SCI-1250-E11UC with an achievement up to 550 kilowatts and a current up to 1,250 ampere. Between these types numerous further AC input chokes are available like the AC input choke SCI-0030-EM47C with a power of 11kW, the AC input choke SCI-0150-E95UC with 55kW or the AC input choke SCI-0490-E28UC with 220 kilowatts of achievement, so that you find a suitable input choke for each of your applications in the Sourcetronic online shop. Weight and dimensions of the chokes vary depending upon power. While the SCI-0005-E2M8C input choke possesses compact dimensions of 110 x 84 x 130 millimeters with a weight of only 2.48 kilograms, amount to the dimensions with the SCI-1250-E11UC choke 330 x 275 x 425 millimeters with a weight of 76 kilograms.

Line reactor LR3 40-4/2
Line reactor LR3 40-4/2

€49.90*
  • Rated voltage: 3 x 400 Vac
  • Rated voltage (IEC): 3 x 690 Vac
  • Rated voltage (UL): 3 x 600 Vac
  • Short circuit voltage uK: 4 % @ 400 Vac
  • Voltage drop: 9,2 Vac @ 400 Vac
  • Rated current: 3 x 6 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 4,900 mH
  • Inductance deviation: ±10 %
Line reactor LR3 40-4/16
Line reactor LR3 40-4/16

€73.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 16 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 1,840mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/30
Line reactor LR3 40-4/30

€179.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 30 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,980mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/40
Line reactor LR3 40-4/40

€199.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 40 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,740mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/45
Line reactor LR3 40-4/45

€229.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 45 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,650mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/50
Line reactor LR3 40-4/50

€265.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 50 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,590mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/63
Line reactor LR3 40-4/63

€269.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 63 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,470mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/80
Line reactor LR3 40-4/80

€369.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 80 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,370mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/100
Line reactor LR3 40-4/100

€579.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 100 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,300mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/115
Line reactor LR3 40-4/115

€509.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 115 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,260mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/160
Line reactor LR3 40-4/160

€589.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 160 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,190mH
  • Inductance deviation: ±10%
Line reactor LR3 40-4/180
Line reactor LR3 40-4/180

€790.90*
  • Rated voltage: 3x 400 Vac
  • Rated voltage (IEC): 3x 690 Vac
  • Rated voltage (UL): 3x 600 Vac
  • Short circuit voltage uK: 4% @ 400 Vac
  • Voltage drop: 9.2 Vac @ 400 Vac
  • Rated current: 3x 180 A
  • Rated frequency: 50 - 60 Hz
  • Inductance: 0,170mH
  • Inductance deviation: ±10%

Conversion of the shop system

Sourcetronic has converted the shop system to Shopware 6. Existing customers with a customer account and from other EU countries are asked to pay attention to the tax calculation for new orders. In some cases it can happen that the VAT number is no longer stored in the account. This can be entered in the account under "Personal profile".

* All prices excl. VAT plus shipping costs and possible delivery charges, if not stated otherwise.

Visa
Mastercard
Paypal
Sofortueberweisung
Ups
Facebook Instagram Youtube Ausbildungsbetrieb
Drive Technology
  • Frequency Inverters
  • Pump Controls
  • EMI Input Filters
  • Brake Resistors
Measurement Technology
  • Hipot Testers
  • Multimeters
  • LCR Meters
  • Safety Testers
Service
  • Calibration Services
  • Rental Equipment
  • SALE
Interesting
  • Blog
  • Company
  • Contact
  • FAQ
  • Glossary
  • Terms & Conditions
  • Return Policy
  • Delivery
  • Payment Terms
  • Privacy Policy
  • Order Process
  • Legal Notice
© 2023 Sourcetronic GmbH. All rights reserved.

Functional cookies are absolutely necessary for the functionality of the web shop. These cookies assign a unique random ID to your browser so that your unhindered shopping experience can be guaranteed over several page views.

Activated cookies:
Saves which cookies have already been accepted by the user for the first time.
PayPal payments
Timezone:
The cookie is used to provide the system with the user's current time zone.
Cookie settings:
The cookie is used to store the cookie settings of the site user over several browser sessions.
Cache handling:
The cookie is used to differentiate the cache for different scenarios and page users.
CAPTCHA integration
CSRF token:
The CSRF token cookie contributes to your security. It strengthens the security of forms against unwanted hacker attacks.
Information on origin:
The cookie stores the referrer and the first page visited by the user for further use.
PayPal:
The cookie is used for payment processing via PayPal.
Session:
The session cookie stores your shopping data over several page views and is therefore essential for your personal shopping experience.

Cookies used for statistics and shop performance metrics.

Google Tagmanager
Google Analytics
Wishlist

Marketing cookies are used to display advertisements on the website in a targeted and individualized manner across multiple page views and browser sessions.

Google conversion tracking:
The Google Conversion Tracking Cookie is used to track conversions on the website effectively. This information is used by the site operator to target Google AdWords campaigns.

Tracking cookies help the shop operator to collect and evaluate information about the behaviour of users on their website.

Microsoft Advertising Tag UET
Bing Ads:
This cookie is used by Bing to gather anonymous information on how visitors are using the website.
Google Analytics:
Google Analytics is used for traffic analysis of the website. Thereby statistics about website activities can be created and read out.
We respect your privacy
This website uses cookies to ensure the best experience possible. More information...

 

 

 

SOURCETRONIC GmbH • Fahrenheitsstrasse | • 28359 Bremen • Germany • T +49 421 2 77 99 99 • www.sourcetronic.com