Highlights
- Frequencies: 50Hz - 100kHz
- Basic accuracy: 0.05%
- Test parameters: |Z|, |Y|, C, L, D, Q, θ(DEG), θ(RAD), Δ%, DCR
- 4.3" TFT LCD-display
- Interface: RS232, USB, HANDLER, GPIB (optional)
- Auto-Power-On Function
- Measuring time: 13ms
Specification
- 4.3" TFT LCD Display
- Soft power switch
- Max. 100kHz test frequency
- 6 digit reading resolution
- 10mVrms-2.0Vrms programmable test level
- DCR: 1V test level, resolution 10μΩ
- DCR polarity configuration function, particularly for inductance test
- Highest test speed 13ms/time
- Selectable 30Ω/100Ω signal source impedance
- V/I monitor
- Built-in comparator, 10 bins sorting and count function
- File storage and program update through U disk
- RS232, USB, HANDLER, GPIB interface (optional)
Measurement display ranges
|Z|, R, X, DCR: | 0.00001Ω - 99.9999MΩ |
|Y|, G, B: | 0.00001nS - 99.9999S |
L: | 0.00001µ - 9.9999kH |
C: | 0.00001pF - 9.99999F |
Q: | 0.0001 - 99999 |
D: | 0.00001 - 9.99999 |
θ(DEG): | -179.999° - 179.999° |
θ(RAD): | -3.14159° - 3.14159° |
Δ%: | -999.999° - 999.999° |
What's in the box
- ST26010 Gilded shorting plate
- ST26011C 4-terminal Kelvin clip test leads (click picture)
- ST26048A 4-terminal test fixture
- Operation manual (as PDF for download)
- Power cord
- Factory calibration certificate
Technical specification |
||||
Model | ST2830 | ST2831 | ST2832 | |
Basic measurement accuracy |
LCRZ | 0.05% | 0.1% | 0.05% |
DCR | 0.1% | |||
Calibration condition | Warm up time: ≥ 30 s ; Environment temperature: 23±5ºC Signal voltage: 0.3Vrms - 1Vrms ; Correction: after OPEN, SHORT Testing cable length: 0 m |
|||
Basic measurement accuracy |
LCRZ | 0.05% | 0.1% | 0.05% |
DCR | 0.1% | |||
Calibration condition | Warm up time: ≥ 30 s ; Environment temperature: 23±5ºC Signal voltage: 0.3Vrms - 1Vrms ; Correction: after OPEN, SHORT Testing cable length: 0 m |
|||
Test signal frequency | 50Hz-100kHz 34 points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz, 2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz |
50Hz-200kHz 37 points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz, 2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz,120kHz, 150kHz, 200kHz |
20Hz-200kHz, 15025 points | |
Signal source output impedance | Selectable 30Ω, 100Ω, ±1% @1kHz | |||
AC test signal level | Normal | 10mV - 2Vrms | ||
Resolution: 10mV, Accuracy: 10% x setting voltage+2mV |
||||
100µA - 20mArms | ||||
Resolution: 0.1mA | ||||
Constant Level (ALC ON) |
- | - | 20mV - 1Vrms | |
- | - | Resolution: 10mV Accuracy: 10% |
||
- | - | 200µA - 1.Arms | ||
- | - | Resolution: 0.1mA | ||
DCR test signal level | 1V DC | 1V DC | 50mV - 2V DC | |
- | - | Resolution: 0.5mV | ||
DC bias voltage source | - | - | 0V - ±5V | |
- | - | Resolution: 0.5mV, Accuracy: 1% |
||
- | - | 0mA - ±50mA | ||
- | - | Resolution: 0.5µA | ||
Test parameters | |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR | |||
DCR display range | 0.00001Ω - 99.999MΩ | |||
LCR parameters display range | |Z|, R, X 0.00001Ω — 99.9999MΩ |Y|, G, B 0.00001μs — 99.9999s C 0.00001pF — 9.99999F L 0.00001μH — 99.9999kH D 0.00001 — 9.99999 Q 0.00001 — 99999.9 θ(DEG) -179.999º — 179.999º θ(RAD) -3.14159 — 3.14159 Δ% -999.999% — 999.999% |
|||
Display digits | 6 | 5 | 6 | |
Measurement time (≥10 kHz) | Fast: 75 meas/sec (13ms) Medium 11 meas/sec 90 ms) Slow: 2.7meas/sec 370 ms) |
|||
Equivalent circuit | Serial, Parallel | |||
Range mode | Auto, Hold | |||
Trigger mode | Internal, Manual, External, Bus | |||
Averaging | 1 - 255 individual measurements | |||
Correction | Open, Short, (known) Load | |||
Math operation | Direct reading, difference to set reference value as ΔABS, Δ% | |||
Trigger delay time setting | 0 - 60.000s, 1ms steps | |||
Step delay time setting | 0 - 60.000s, 1ms steps | |||
List Sweep |
|
|||
Comparator function | 10 bins, BIN1–BIN9, NG, AUX | |||
Bin count function | ||||
PASS, FAIL front panel or scan fixture LED display | ||||
Built-in Storage | Internal 40 LCRZ instrument setting files, 201 times test results | |||
USB Storage | Instrument setting files , measurement result CSV files, screenshots (GIF format) | |||
Interface | Control interface | HANDLER | ||
Communication interface |
USB DEVICE, RS232C, GPIB (option) | |||
Storage interface | USB HOST (U-disk storage) |