Hipot Tester UH28CS-AC-12-0050
€4,780.00*
Details
+49 421 277 9999
The High Voltage Tester UH28CS have an additional digital I/O control interface; e.g. for the use of PLC Control. Through the signals "Start / Stop, Pass / Fail and Test" it is possible to integrate them into test systems with shortest cycle time. The zero voltage channel will be turned on or off as needed for optimal protection from overvoltage of the device under test. Optional you can get the UH28CS with carrying handle (holder).
Highlights
- 12kV Hipot Tester UH28CS
- 600VA transformer
- Reliable burn function
- 2 instruments: current and voltage
- Potential free in accordance to EN50191
- Release current adjustable
- 2 ranges: 5mA and 50mA
- Terminals (PLC, footswitch, cave, 2-hand-operation)
- 19" industrial housing (optional)
Test methods
- AC voltage: 0V - 12000V
- Resolution: 200V
- AC current: 0,1mA - 50mA
- Resolution: 1mA
- Accuracy: 2.5%
- Short current: 200mA
- Current range switchable:
- Range: 0 - 5mA
- Range: 0 - 50mA
- 50Hz and 60Hz
- Switchable tests:
- "test"
- "burn"
Technical data
- Optic and acoustic error message
- Zero voltage switch (protects your test object)
- 2 precise instruments 50 x 100 mm
- 3 signal lamps (operation, safety, HV)
- 2 buttons (operation, HV)
- Digital I/O:
- START / STOP
- PASS / FAIL
- Test in progress
- Terminals:
- 2 HV sockets potential free
- Warning lamp
- Foot switch, test-cage, light curtain, prod.-line, two-hand-operation
- Highest safety standard:
- Key switch preventing unauthorized use
- High voltage absolutely potential-free
- Two fold isolated transformer and measurement converter
- Status indication
- Socket for external pilot lamp
- Integrated warning buzzer
- Insulated sockets
- Security activation knob in compliance with VDE0104
- Supply: 230V, 50/60 Hz, 8A max.
- Operating temperature: +5° up to +45°
- Air humidity: 70% (non-condensing)
- Attitude: 2000m
- Compact industrial casing (W/H/D): 585/212/325 mm
- Weight: 27 kg
- CE-compliant, in accordance with EN 50 191
What's in the box:
- Safety circuit plug
- Power cable
- Operation manual
- Calibration certificate
Options
- HTP06N HV probe
- HVP06C HV cable with plug
- KLD-SW delphin clamp black
- WK28 warning lamp
- RC carrying handle (holder)
- HVS06N HV sockets backside
- UH28CS-R comfortable 19" rack housing
HV Test: | AC |
---|---|
Test current: | >3mA - 100mA |
Test voltage: | >6kV - 12kV |
Related products
- Rectangle design
- "Danger High Voltage"
- Material: plactic
- Size: 74mm x 210mm
- Colour: yellow/black
- EN50191 / DIN 40008
- Standard-compliant, multi-vendor calibration based on ISO 17025
- Calibration of Hipot Tester / HV tester
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Triangle design
- With flash arrow
- Material: plactic
- Size: 200mm x 200mm
- Colour: yellow/black
- DIN 40008
- With safety socket and test nipple
- For easy testing of test objects
- In plastic casing
- Devices: 28 series
- Standard: EN 50191, VDE0104
- Lights: Red/Green
- Function: operation, switch on, ready
- Cable length: 2m
- Hipot Tester: UH28C
- With foot protection cover
- Start via control-IO
- With plug: 12-pole
- Access to control interface
- Cable length: 2m
- Single-pole, in conduit
- Length 2,5 m
- HV-plug HIRAT
- 16 kV AC / 22 kV DC, max. 10 A,
- Including cable set for hipot tester 28 series
- Start button
- Dimension (W/H/D):
Outside: 450 / 515 / 495 mm
Inside: 360 / 350 / 450 mm - Completely mounted and wired for plug&play
- PVC design-housing
- Viewable transparent swinging hood
- Damping gas spring
- Safety limit switch
- CE conform with EN 50191
- HV-Cable, single-pole, in conduit
- Length 2,5 m
- 16 kV AC / 22 kV DC, max. 10 A
- All-Round-Test-Cage to connect
with safety testers and hipot testers - Dimension (W/H/D):
Outside: 670 / 515 / 495 mm
Inside: 565 / 350 / 450 mm - Viewable transparent swinging hood
- Damping gas spring
- Safety limit switch
- CE conform with EN 50191
- All-Round-Test-Cage to connect
with safety testers and hipot testers - Dimension (W/H/D):
Outside: 450 / 515 / 495 mm
Inside: 360 / 350 / 450 mm - Viewable transparent swinging hood
- Damping gas spring
- Safety limit switch
- CE conform with EN 50191
- Conforming to all standards
- Emergency stop for tester
- Load: 16 A
- Cable length: 5 m
- Rectangle design
- "No unauthorised entry"
- Material: plactic
- Size: 200mm x 300mm
- Colour: red/white
- Portable posts chain
- Convex base plate
- Colour: Yellow-Black
- Two-parts
- Height: 1100mm / D=32cm
- With safety socket
- For easy testing of test objects
- L and N bridged/connected
- In plastic casing
- Including cable-set for hipot tester 28 series:
UH28C, UH28, UH28CS, A, M, P - Ergonomically design
- Push-start-buttons: 2
- Normed distance between buttons
- Connecting cable: 2.5 m
- HV-Cable, single-pole
- Length 3 m
- HV-plug HIRAT
- 16 kV AC / 22 kV DC, max. 10 A
- Hipot Tester: UH28C
- Start via control-IO
- With plug: 12-pole
- Access to control interface
- Cable length: 2m