Hipot Tester UX36-AC-12-0050-TGT
Product number:
64583
EAN:
4260689525898
€6,310.00*
Goods expected soon
Details
Fachberatung unter
+49 421 277 9999
+49 421 277 9999
Print
Description
Product information "Hipot Tester UX36-AC-12-0050-TGT"
The UX36 is a high-voltage tester with dry transformer for AC high-voltage testing with test voltages from 500 to 12,000 V AC, trip currents from 0.5 to 50 mA, and a transformer power of 600 VA. The test voltage is regulated, the benchtop unit is grounded on one side and not suitable for operation with test pistols. Ramp function, burn function, and keypad lock support process-reliable testing; the safety circuit is designed in accordance with EN 50191. The device is suitable both for stand-alone operation and for remote control via PC software or customer-specific applications.
Highlights
- HV AC - high-voltage testing: 500 - 12,000 V AC, 0.5 - 50 mA, ramp
- Test voltage adjustable from 0.5 - 12 kV AC, trip current adjustable from 0.5 - 50 mA, test time adjustable: 1 s - 99 min, infinite
- Rated power of the transformer: 600 VA
- Benchtop unit with dry transformer, dimensions (W x H x D): 590 x 210 x 420 mm
- Grounded on one side (not suitable for operation with test pistols)
- Regulated test voltage, electromechanical
- Switching on and off at the zero crossing, sinusoidal output voltage with 50 Hz (depending on the mains supply)
- Ramp function, burn function for max. 1 second
- High-voltage outputs on the rear
- CE-compliant according to EN 50191
- Including factory calibration certificate, safety circuit connector, key set
- Large LED display for showing all setpoint and actual values
- Visual and acoustic error signaling
- 15 program memories for predefined parameter sets
- Device peripherals for PLC, RS232, CAN and drivers, digital interface for status displays and remote control
- Data management program or printout via printer only possible with external PC
- PC drivers for customer-specific applications (DLL, Active-X and LabVIEW) optionally available
- Optional customer-specific extensions possible
- Connection for safety circuits and signal lights according to EN 50191
Technical data and standards
Test voltage |
|
| Setting range: | 500 - 12,000 V AC |
| Voltage frequency: | 50 Hz, depending on the mains supply |
| Waveform: | sinusoidal, depending on the mains supply |
| Voltage stability: | Regulated output voltage (electromechanical), continuous PI control for a constant test voltage independent of mains voltage fluctuations |
| Rated transformer power: | 600 VA |
| Zero-voltage switch: | Switching the test voltage on and off takes place at the zero crossing |
Test current |
|
| Setting range, limit value: | 0.5 - 50 mA (trip current) |
| Burn function: | max. burn time 1 s |
Test time |
|
| Test time setting range: | 1 s - 99 min, infinite |
Extended functions |
|
| Ramp function: | The voltage ramp can be activated, the parameters (e.g. rise and fall time) are freely selectable. The ramp function ensures particularly gentle testing and is mandatory when a product standard specifies a special voltage curve |
| Detection of breakdown voltage: | The voltage value at which an error was detected is retained flashing on the display |
| Error detection: | Shutdown via limit value and peak detection. In addition to exceeding the current limit value, the response of a special overcurrent detection also leads to an error, so that even low-energy breakdowns are reliably detected |
| Keypad lock: | Prevents accidental adjustment of the test parameters and can be configured individually, e.g. all keys can be locked or individual functions (e.g. calling up test programs) can still be permitted |
| Current and voltage measurement: | directly on the high-voltage side for precise test results |
Standards and electrical safety |
|
| EN 50191: | CE-compliant, safety technology implemented as required by the standard, with two forcibly guided safety relays |
Device characteristics
General device data |
|
| Design: | Benchtop unit with dry transformer |
| Grounding: | grounded on one side, not suitable for operation with test pistols |
| Displays: | large LED display for showing all setpoint and actual values |
| Storage of test parameters: | 15 program memories for predefined parameter sets |
| Error signaling: | visual and acoustic |
| Dimensions (W x H x D): | 590 x 210 x 420 mm |
Operation, start options & interfaces
Extended device setup |
|
| Individual setting: | Start options, keypad lock, language and mode selection for external printer, behavior of the digital inputs and outputs, ramp options, brightness of the display elements, and much more |
| Update capability: | Updatable via interface for customer-specific changes and updates |
| Customer-specific extensions: | optionally possible |
Interfaces |
|
| Device peripherals: | PLC, RS232, CAN, drivers |
| Digital interface: | for status displays and remote control |
| Remote control: | Via PC software (ETL DataView user interface), a customer-specific application (DLL, C#, .NET, LabVIEW), simple command parameters (ASCII) or digitally from a PLC (Digital-IO) |
| PC drivers: | for customer-specific applications (DLL, Active-X and LabVIEW) optionally available |
| Data management and printout: | Data management program or printout via printer only possible with external PC |
Connections - test objects & safety components
| High-voltage outputs: | on the rear |
| Safety circuit and signal lights: | Connection for safety circuits and signal lights according to EN 50191 |