Hipot tester
The compact design of the ST9200 hipot tester makes it suitable for use in almost every area and scenario. The wide variety of possible interfaces and uses include as an RS232, a handler, remote I/O, USB, or GPIB, this hipot tester is ideally suited for use in all automatic test systems. The tester is also perfect for use in a manual workstation, this would utilise the warning light and the safety test probes designed to be operated in a two-handed system. All of the 9200 hipot tester are built with the ARC detection feature, which will automatically micro-discharge a partial part of the insulation. The ST9200 also allows you to control the high voltage using a ramp function, conveniently located on the tester. GO-NOGO-Comparators are projected on the display using a red/green LED, optional the built-in speaker will emit an acoustic warning. The hipot tester houses a large LCD display to offer clear reading of the values from all angles. The ST9201S also has a built-in switch matrix with 8 channels which allows you to switch the high voltage from one point to another.
Important information about high-voltage testers can be found here:
- High voltage test 6000V AC
- AC current 0.5 - 100 mA
- 600VA construction power
- Digital voltage regulation
- Control by RS232 interface
- 4-wire-technique
- Digital I/O and CAN bus
- Programmable ramp
- Automatic START function
- Safety in accordance with EN50191
- High voltage test 6000V DC
- DC current 0.1 - 10 mA
- Digital voltage regulation
- Control by RS232 interface
- 4-wire-technique
- Digital I/O and CAN bus
- Programmable ramp
- Automatic START function
- Safety in accordance with EN50191
- High voltage test 5000V AC
- AC current: 2.5mA
- Max. 3mA safety current limited
- 500VA construction power
- Digital voltage regulation
- Control by RS232 interface
- 4-wire-technique
- Digital I/O and CAN bus
- Programmable ramp
- Automatic START function
- Safety in accordance with EN50191
- HV Test: 5kV AC
- Release current: 200mA
- 2k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- 15kV AC
- Ramp function
- 4-wire contact monitoring
- Open circuit monitoring
- Automatic start
- Test parameters programmable
- RS232, digital I/O (PLC), CAN
- Software, DLL, LabView, Active-X (option)
- HV Test: 20kV AC
- Short circuit current: 100mA
- 2k VA power
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 5kV AC / 7kV DC
- Release current: 100mA
- 0,5k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 6kV AC / 8,4kV DC
- Release current: 100mA
- 0,6k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 10kV AC / 14kV DC
- Short circuit current: 100mA
- 1k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 12kV AC / 16kV DC
- Short circuit current: 100mA
- 1,2k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 10kV DC
- Release current: 50mA
- 0,5k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 100kV AC
- Test current: 0.5mA - 100mA
- 10k VA power / potential free
- With oil transformator
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 30kV AC
- Test current: 0.5mA - 50mA
- 1,5k VA power / potential free
- With oil transformator
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
Sourcetronic Hipot Tester ST9201
In this video you will be introduced to the high voltage tester ST9201, whose functions and typhus.
How does an Hipot Tester works?
High-voltage tests are performed for appliances with protection classes I (with a PE protective conductor) and II (without a PE protective conductor). In the process they determine whether the insulation of the current-carrying conductor and the safe distance from the device casing meet the specifications.
A high voltage test is considered "good" when no current flows. In an AC high-voltage test on a device under test with capacitive characteristics, however, a weak current will flow. Therefore, most test devices have adjustable settings. As a guide for the voltage during a high-voltage test, double the usual voltage of the DUT you are testing and add 1,000 V. For a 230-volt device, that is: 1000 V + 2 x 230 V = 1460 V (1500 V).A distinction is drawn between AC and DC high-voltage tests. The VDE (Association for Electrical, Electronic & Information Technologies) recommends the DC high-voltage test for production facilities. It is less risky and cannot damage the human heart. For job safety, the requirements of the professional association apply (to EN 50191). Additional workplace security is not needed during voltage testing with AC up to 3 mA or DC up to 12 mA. The DC high-voltage test, thus, has the added advantage that no extra precautions are required for tests of 12 mA or less.
Safety at work:
a) High-voltage tests with currents : |> 3 mA / AC or |> 12 mA / DC
- Special high-voltage test room, or
- Sealed-off area, warning sign, warning lights, test probes / test cage / two-handed operation.
b) High voltage tests with currents: class I
- No safety precautions, or
- Provisional precautions against "secondary accidents", e.g. twitches and lurches after an electrical shock.
High-voltage tests on specimens with suppression capacitors and Y-capacitors can be done with either AC or DC. The charge current measurement, as part of the DC high-voltage test, can also provide information about the built-in noise suppression capacitor.