-
Measurement Technology
-
Battery tester
-
Calibration Services
-
Capacitance Meter
-
DC Bias Current Source
-
Digital Power Meter
-
Earth Tester
-
Ground Bond Tester
-
HV Probe
-
High Voltage Relays
-
Hipot tester
-
Impedance Analyzer
-
Insulation Tester
-
LCR Meter
-
Measurement Software
-
Megohmmeter
-
Microohmmeter
-
Milliohmmeter
-
Multimeter
-
Relay Matrix
-
Rental Equipment
-
Safety Tester
-
Surge Tester
-
Test Systems
-
Transformer Tester
-
Transport Cases
-
Battery tester
Certified quality management system
Measurement Technology
Measurement engineering is a major division of Sourcetronic. Your measurement engineering specialist, specialized on highly diverse measurements, such as resistor measurements, LCR, high voltage, isolation resistors, security tests but as well multimeters, oscilloscopes and software.
- PE test lead, 4-pole, grey (D = 7.5 mm), with open cable end for self-assembly
- PE plug PES4, 4-pin, for plugging into the test instrument
- Max. operating current for PE tests: 32 A AC (source path)
- Selectable cable length: 2 m, 3 m or 5 m (other cable lengths on request)
- PE test lead, 4-pole, grey (D = 7.5 mm), with open cable end for self-assembly
- PE plug PES4, 4-pin, for plugging into the test instrument
- Max. operating current for PE tests: 32 A AC (source path)
- Selectable cable length: 2 m, 3 m or 5 m (other cable lengths on request)
- PE test lead, 2-pole, black (D = 8.5 mm)
- Solid cable lug for contacting or screwing on, e.g. to a contact clamp or a coupling prism
- Source path with 6 mm plug for plugging into the test instrument (single-pole)
- Sense path with BNC plug for plugging into the test instrument
- Max. operating current: source path 100 A AC
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- PE test lead, 7-pole, grey (D = 8.5 mm), with open cable end for self-assembly
- PE plug PES7, 7-pin, for plugging into the test instrument
- Max. operating current for PE tests: 32 A AC (source path)
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- PE test lead, 7-pole, grey (D = 8.5 mm)
- PE plug PES7, 7-pin, for plugging into the test instrument
- Opposite end with 4 mm lamella plug, e.g. for attaching a test clamp
- Max. operating current for PE tests: 32 A AC (source path)
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- High-voltage test instrument with turbo mode, 5 kV AC / 100 mA / 500 VA
- Turbo mode for series testing: total test time 300 ms + 10 % at 150 ms test time (digital PLC operation)
- Test voltage 100 - 5,000 V AC, test current 0.5 - 100 mA
- Regulated, potential-free high voltage for operation with test guns
- Ramp function, shutdown via limit value and peak detection
- Contact and cable break monitoring, automatic start for test guns
- Safety circuit per EN 50191 with two positively guided safety relays
- Start via test gun, test cage, start button or digital I/O (PLC)
- RS232 interface, digital I/O (PLC) and CAN; remote controllable (ASCII, Windows DLL, .NET Framework Assembly, DataView)
- 15 freely programmable parameter sets
- HV test gun with automatic start, contact check and cable break monitoring
- HV cable, 2-pole, blue (D = 9.6 mm)
- HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
- Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
- Start signal generated when pressed against the test object; high voltage only switches on after contact (with suitable test instrument)
- Tungsten test probe (10 mm, extendable), retracted into an arc-resistant Teflon shaft between tests
- Trigger secured against accidental actuation
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- HV test gun HTP06C with automatic start, contact check and cable break monitoring
- HV cable, 2-pole, blue (D = 9.6 mm)
- Without HV plug for plugging into the test instrument, open cable end
- Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
- Selectable cable length: 2 m or 3 m (other cable lengths on request)
- HV cable, 2-pole, blue (D = 9.6 mm), with open cable end for self-assembly
- HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
- Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- HV cable, 2-pole, blue (D = 9.6 mm), with open cable end for self-assembly
- HV angled plug HVP06CW (D = 6 mm), 2-pin, for plugging into the test instrument
- Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- HV cable, 2-pole, blue (D = 9.6 mm)
- HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
- Opposite end with 4 mm lamella plug, e.g. for attaching a test clamp
- Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
- Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
- HV cable, 2-pole, blue (D = 9.6 mm)
- HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
- With contact clamp (solid design) on the opposite end for contacting the test object, clamp width: 38 mm
- Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
- Selectable cable length: 2 m, 3 m or 10 m (other cable lengths on request)
- Test cage with transparent hood for test instruments of the 36 series
- Fully assembled with safety switch (2 paths)
- Positive protection against contact per EN 50191
- Gas springs for damping and end-position damping
- Interior (W x H x D): 330 x 350 x 450 mm
- Test connections HV1 and HV2/PEX1 with safety sockets and quick-action test clamps
- Connecting leads for the test instrument included (safety circuit, 2 x HV cable, 2 m)
- IP30, weight: 14.5 kg
- Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A