UX36 Hipot Tester
The UX36 Hipot tester are available in different sizes and power classes. Whether 10KV, 20KV, 30KV, 50KV up to 100KV, with high-voltage AC or DC, the UX36 series offers many possibilities. Due to the variable equipment concept you will find exactly the right device to fulfill your requirements. The significant high-voltage components, such as oil-bearing HV transformers, can be controlled remotely with the elegant UX36 software. Packaged in an ergonomic trolley it can be used flexibly in production or in the laboratory. Appropriate safety elements, such as e.g. Warning lights and valves, two-hand controls, test cages and signs are included. The UX36 test sets are remarkable for their compact coordinated design and provide a powerful output power of 20,000 VA.
- HV Test: 5kV AC
- Release current: 200mA
- 2k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 5kV AC
- Release current: 200mA
- 2k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- High-voltage tester with dry-type transformer, 6 kV AC / 200 mA / 1,200 VA
- Test voltage 100 - 6,000 V AC, test current 0.5 - 200 mA
- Controlled, potential-free high voltage for operation with test pistols
- Ramp function, shutdown via limit value and peak detection
- Contacting and cable break monitoring, automatic start for test pistols
- Safety circuit according to EN 50191 with two forcibly guided safety relays
- Remote controllable (ASCII, Windows DLL, .NET Framework Assembly, DataView)
- 15 freely programmable parameter sets
- High-voltage tester, 5 kV DC / 100 mA / 500 VA
- Test voltage 300 - 5,000 V DC, test current 0.1 - 100 mA
- Regulated, floating high voltage for operation with test pistols
- Ramp function, shutdown via threshold value and peak detection
- Discharge, contacting and cable break monitoring, automatic start for test pistols
- Safety circuit according to EN 50191 with two forcibly guided safety relays
- Remote-controllable (ASCII, Windows DLL, .NET Framework Assembly, DataView)
- 15 freely programmable parameter sets
- HV Test: 20kV AC
- Short circuit current: 100mA
- 2k VA power
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 5kV AC / 7kV DC
- Release current: 100mA
- 0,5k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 6kV AC / 8,4kV DC
- Release current: 100mA
- 0,6k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 10kV AC / 14kV DC
- Short circuit current: 100mA
- 1k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 12kV AC / 16kV DC
- Short circuit current: 100mA
- 1,2k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 10kV DC
- Release current: 50mA
- 0,5k VA power / potential free
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- HV Test: 30kV AC
- Test current: 0.5mA - 50mA
- 1,5k VA power / potential free
- With oil transformator
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
- 15kV AC
- Ramp function
- 4-wire contact monitoring
- Open circuit monitoring
- Automatic start
- Test parameters programmable
- RS232, digital I/O (PLC), CAN
- Software, DLL, LabView, Active-X (option)
- HV Test: 50kV AC / 70kV DC
- Release current: 100mA
- 20k VA power / potential free
- With oil transformer
- Burning function and ramp
- Digital voltage control
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
- Work place according to EN 50191
Erläuterung zur Produktbezeichnung
Die Bezeichnungen für die Hochspannungsprüfgeräte der UX36-Reihe beinhalten eine Beschreibung der Eigenschaften des Gerätes. Die Zusammensetzung wird im Folgenden an zwei Beispielen erläutert:
Gerät: UX36-AC-03-0500-TPT
-AC: Wechselspannung
-03: 3kV
-0500: 500mA Auslösestrom
-TPT: Trockentransformator potentialfrei Tischgerät
Gerät: UX36-ADC-1521-0100-OPT
-ADC: Wechsel- und Gleichspannung
-1521: 15kV Wechselsspannung und 21kV Gleichspannung
-0100: 100mA Auslösestrom
-OPT: Öltransformator potentialfrei Tischgerät
Die letzten drei Buchstaben und deren Bedeutungen setzen sich wie folgt zusammen:
1. Stelle |
2. Stelle |
3. Stelle |
Bedeutung |
| O | Öltransformator | ||
| T | Trockentransformator | ||
| P | Potentialfrei | ||
| G | Geerdet | ||
| T | Tischgerät | ||
| W | Eingebaut im Wagen |