The UX36 is a high-voltage tester with dry transformer for AC high-voltage testing with test voltages from 100 to 6,000 V AC, test currents from 0.5 to 200 mA, and a power rating of 1,200 VA. The test voltage is regulated and the high voltage is floating, making the device suitable for operation with test pistols. Ramp function as well as contact and cable break monitoring support reliable testing processes; the safety circuit is designed in accordance with EN 50191. The device is suitable for stand-alone operation as well as for remote control via PC software or customer-specific applications.

Highlights

  • HV AC - High-voltage testing: 100 - 6,000 V AC, 0.5 - 200 mA, floating, ramp
  • Shut-off via limit value and peak detection
  • Ramp function, keypad lock, minimum current monitoring
  • Remote-controllable (ASCII, Windows DLL, .NET Framework Assembly, DataView)
  • Source-sense operation, automatic start for test pistols
  • Contact and cable break monitoring
  • 15 freely programmable parameter sets
  • Error message: acoustic, optical, and via interface
  • Safety circuit with two forcibly guided safety relays
Technical data and standards

Test voltage

Setting range:100 - 6,000 V AC
Voltage stability:Output voltage regulated, continuous PI control for a constant test voltage regardless of mains voltage fluctuations
Power:1,200 VA

Test current

Setting range, limit value:0.5 - 200 mA

Extended functions

Ramp function:The voltage ramp can be switched on; the parameters (e.g. rise and fall time) can be selected freely. The ramp function ensures particularly gentle testing and is mandatory when a product standard specifies a special voltage curve
Breakdown voltage detection:The voltage value at which an error was detected is retained flashing on the display
Error detection:Shut-off via limit value and peak detection. In addition to exceeding the current limit value, the response of a special overcurrent detection also leads to an error, so that even low-energy breakdowns are detected reliably
Contact monitoring:Monitoring of contact with the test object
Conductor break monitoring:Monitoring of the test leads for conductor breakage, high-voltage lines in 4-wire technology (source-sense) for maximum process reliability
Keypad lock:Prevents accidental adjustment of the test parameters and can be configured individually; for example, all keys can be locked or individual functions (e.g. calling up test programs) can still be permitted
Automatic start:The start signal is triggered by pressing the test pistols. The voltage is only switched on when both test probes are securely in contact with the test object. This protects the test object from overvoltage peaks and ensures the required test time
Current and voltage measurement:directly on the high-voltage side for precise test results
Floating potential:High voltage floating, prerequisite for operation with test pistols and maximum safety for the test operator

Standards and electrical safety

EN 50191:Safety technology designed as required by the standard, with two forcibly guided safety relays
Operation, start options & interfaces

Extended device setup

Individual setting:Start options, keypad lock, language and mode selection for external printer, behavior of the digital inputs and outputs, ramp options, options for contact and cable break monitoring, brightness of the display elements, and much more
Update capability:Updatable via interface for customer-specific changes and updates

Interfaces

Remote control:Via PC software (ETL DataView user interface), a customer-specific application (DLL, C#, .NET, LabVIEW), simple command parameters (ASCII), or digitally from a PLC (Digital-IO)

Related Products

Test Cage MAXCAB-800 unwired

€3,200.00*
  • Test cage with transparent cover
  • Completely assembled with safety switch (2 paths)
  • Mandatory protection against accidental contact according to EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 800 x 350 x 450 mm
  • Safety switch connections terminated on terminal block
  • IP30, weight: 21.3 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage MAXCAB-1000 unwired

€3,620.00*
  • Test cage with transparent hood
  • Fully assembled with safety switch (2 paths)
  • Positive protection against contact per EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 1,000 x 350 x 450 mm
  • Safety switch connections wired to contact terminal
  • IP30, weight: 24 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage SICAB-36-CC

€2,540.00*
  • Test cage with transparent hood for test instruments of the 36 series
  • Fully assembled with safety switch (2 paths)
  • Positive protection against contact per EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 330 x 350 x 450 mm
  • Test connections HV1 and HV2/PEX1 with safety sockets and quick-action test clamps
  • Connecting leads for the test instrument included (safety circuit, 2 x HV cable, 2 m)
  • IP30, weight: 14.5 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage SICAB Unwired

€2,150.00*
  • Test cage with transparent hood
  • Fully assembled with safety switch (2 paths)
  • Positive protection against contact per EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 330 x 350 x 450 mm
  • Safety switch connections wired to contact terminal
  • IP30, weight: 14.5 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage DOCAB unwired

€2,520.00*
  • Test cage with transparent hood
  • Fully assembled with safety switch (2 paths)
  • Positive protection against contact per EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 550 x 350 x 450 mm
  • Safety switch connections wired to contact terminal
  • IP30, weight: 19.0 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage DOCAB-36-CC

€2,890.00*
  • Test cage with transparent hood for test instruments of the 36 series
  • Fully assembled with safety switch (2 paths)
  • Positive protection against contact per EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 550 x 350 x 450 mm
  • Test connections HV1 and HV2/PEX1 with safety sockets and quick-action test clamps
  • Connecting leads for the test instrument included (safety circuit, 2 x HV cable, 2 m)
  • IP30, weight: 19.0 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test cage BIGCAB-650 unwired

€3,280.00*
  • Test cage with transparent hood
  • Completely assembled with safety switch (2 channels)
  • Mandatory protection against accidental contact according to EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 650 x 530 x 600 mm
  • Safety switch connections terminated on terminal block
  • IP30, Weight: 27 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage BIGCAB-800 unwired

€3,650.00*
  • Test cage with transparent hood
  • Completely assembled with safety switch (2 paths)
  • Mandatory contact protection according to EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 800 x 530 x 600 mm
  • Safety switch connections applied to contact terminal
  • IP30, weight: 27 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage BIGCAB-1000 unwired

€3,960.00*
  • Test cage with transparent hood
  • Completely assembled with safety switch (2 paths)
  • Inevitable protection against accidental contact according to EN 50191
  • Gas springs for damping and end-position damping
  • Interior (W x H x D): 1,000 x 530 x 600 mm
  • Safety switch connections connected to terminal block
  • IP30, weight: 39 kg
  • Max. rated values HV/ISO: 7 kV AC / 10 kV DC, max. 10 A
Test Cage XCAB-1000 unwired

€5,970.00*
  • Test cage with vertical lifting door and rear wall wiring
  • Completely assembled with safety switch (2 paths)
  • Mandatory protection against accidental contact in accordance with EN 50191
  • Balanced counterweights for ergonomic working
  • Movable front made of transparent plastic
  • Wiring compartment in the floor and rear area, floor and rear wall can be unscrewed
  • Interior (W x H x D): 1,000 x 900 x 1,000 mm
  • Safety switch connections terminated on terminal block
  • IP30, weight: approx. 100 kg
  • Max. ratings: 7 kV AC / 10 kV DC, max. 10 A
Warning Lamp Set WK36-NG

€157.00*
  • Devices: hipot testers 36 series
  • Signal lamp: red / green
  • Conforming to all standards: VDE0104, EN50191
  • Status:
    • READY FOR OPERATION
    • READY TO SWITCH ON
    • IN OPERATION
  • Voltage: 230V
  • Cable length: 2m
Two-hand operation ZB 36

€588.00*
  • Two-hand control for test stations with ergonomic control buttons
  • Standard-compliant spacing and control recesses
  • With supply cable and connector plug for UH36 and UX36
  • Mains supply cable length: 1.5 m
  • Selectable supply cable length: 2.5 m or 5 m
Connection Cable RS232K36

From €28.60*
  • Connection cable for remote control of the test device via PC or PLC
  • 9-pin SUB-D, plug / socket
  • Cable with RX/TX crossed
  • Remote control via DataView, ASCII commands or custom application (ETL driver: DLL, ACTIVE-X, LabVIEW)
  • Selectable cable length: 2 m, 5 m or 10 m
Safety Circuit Plug UH36 unwired

€14.60*
  • Safety circuit connector UH36, unassigned, for customer-specific assembly
  • 3 different safety circuits can be implemented through wiring
  • Testing with test guns: 2 bridges (Pin 4-5 and Pin 6-7)
  • Testing with test cage or two-hand operation: 2 normally open contacts (Pin 2-6 and Pin 3-5)
  • Automation solution: 2 normally open contacts / bridges (Pin 1-6 and Pin 5-8)
Replacement Key for Power Switch UH36

€33.60*
  • Replacement key for the mains switch, for the Series 36
  • Scope of delivery: 2 keys
HV Probe HTP06C

From €168.50*
  • HV test gun with automatic start, contact check and cable break monitoring
  • HV cable, 2-pole, blue (D = 9.6 mm)
  • HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
  • Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
  • Start signal generated when pressed against the test object; high voltage only switches on after contact (with suitable test instrument)
  • Tungsten test probe (10 mm, extendable), retracted into an arc-resistant Teflon shaft between tests
  • Trigger secured against accidental actuation
  • Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
Calibration High Voltage Tester

€79.00*
  • Standard-compliant, multi-vendor calibration based on ISO 17025
  • Calibration of Hipot Tester / HV tester
  • Traceable to DKD
  • Cleaning and adjustment
  • Repair service
HV-Cable HVC06C-B

From €82.00*
  • HV cable, 2-pole, blue (D = 9.6 mm)
  • HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
  • Opposite end with 4 mm lamella plug, e.g. for attaching a test clamp
  • Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
  • Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
HV-Cable HVC06C

From €71.90*
  • HV cable, 2-pole, blue (D = 9.6 mm), with open cable end for self-assembly
  • HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
  • Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
  • Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
ASCII protocol for Series 36 and Series 400

€170.00*
  • Drivers, example programs, and programming manual
  • Functions: high-voltage test, protective earth test, insulation test, current consumption test, 2-wire/4-wire, user interface, external relay matrix
  • Compatible devices: UH36, UB36, UG36, RS36, ST400
Emergency Stop Switch

€256.20*
  • Conforming to all standards
  • Emergency stop for tester
  • Load: 16 A
  • Cable length: 5 m
Test Cage SICAB SICAB400-0710-CC02

€2,416.90*
  • Including cable set for safety tester ST400 series
  • Dimension (W/H/D):
    Outside: 450 / 515 / 495 mm
    Inside: 360 / 350 / 450 mm
  • Completely mounted and wired for plug&play
  • PVC design-housing
  • Viewable transparent swinging hood
  • Damping gas spring
  • Safety limit switch
  • CE conform with EN 50191
Warning Sign WS-NE

€23.50*
  • Rectangle design
  • "No unauthorised entry"
  • Material: plactic
  • Size: 200mm x 300mm
  • Colour: red/white
Log printer, desk, RS232

€495.60*
  • Log printer in own plastic table casing
  • Not to be built-in.
  • Baud rate 9600
Barricade Posts ASP-B

€105.80*
  • Portable posts chain
  • Convex base plate
  • Colour: Yellow-Black
  • Two-parts
  • Height: 1100mm / D=32cm
Test Adapter TA-HST

€170.70*
  • With safety socket
  • For easy testing of test objects
  • L and N bridged/connected
  • In plastic casing
Holder HTP06 Left

€389.60*
  • Side mounting for test waggon or table
  • Ergonomically placed
  • HV probe type: HTP
  • Side: left
  • Colour: white
Foot Switch 36

€209.10*
  • HV Tester: UB36, UG36, UH36, UX36
  • Start via control-IO
  • With plug: SUB-D 9-pole
  • Access to control interface
  • Cable length: 2m
2-Wire Relay Matrix STM

From €4,950.00*
  • Robust 2-wire matrix
  • Measuring points freely connectable
  • Test connection via Harting plug
  • Continuity tests
  • High voltage tests
  • Insulation resistance tests
  • Surge voltage tests
HV-Cable HVC06C-KL

From €193.50*
  • HV cable, 2-pole, blue (D = 9.6 mm)
  • HV plug HVP06C (D = 6 mm), 2-pin, for plugging into the test instrument
  • With contact clamp (solid design) on the opposite end for contacting the test object, clamp width: 38 mm
  • Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
  • Selectable cable length: 2 m, 3 m or 10 m (other cable lengths on request)
DataView Testing Instruments Software Series 36

€752.80*
  • Remote control of Series 36 devices
  • Create and edit test plans
  • Menu-guided test plan selection: mouse/keyboard/scanner
  • Administrator administration and user management
  • Visualized test run and storage of reports
  • Compatible devices: UH36, UX36, ZPA36
  • Export formats: XML, PDF, CSV, HTML
  • Remote control via: RS-232
  • Languages: German, English
  • Operating system: Windows
HV-Cable HVC06CW

From €130.30*
  • HV cable, 2-pole, blue (D = 9.6 mm), with open cable end for self-assembly
  • HV angled plug HVP06CW (D = 6 mm), 2-pin, for plugging into the test instrument
  • Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A
  • Selectable cable length: 2 m, 3 m, 5 m or 10 m (other cable lengths on request)
Test Cage DOCAB400-0710-CC02

€2,754.20*
  • Including cable set for safety tester ST400 series
  • Dimension (W/H/D):
    Outside: 670 / 515 / 495 mm
    Inside: 565 / 350 / 450 mm
  • Viewable transparent swinging hood
  • Damping gas spring incl. final pos. damping
  • Safety limit switch
  • CE conform with EN 50191
Warning Sign WS-F "Flash"

€10.30*
  • Triangle design
  • With flash arrow
  • Material: plactic
  • Size: 200mm x 200mm
  • Colour: yellow/black
  • DIN 40008
Dolphin Clamp KLD-SW

€10.70*
  • Dolphin clamp made of brass with all-round insulation
  • Toothed jaw for coarse contact points and fine-wire surface, suitable for contact points up to 30 mm in diameter
  • Extended design specifically for plugging onto Ø 4 mm lamella plugs
  • Available in black and red
Connecting Cable "CONTROL"

€23.00*
  • For adapt. to a PLC
  • Length 2 m
  • 9-pole SUB-D
Test Adapter TA-HSTPE

€220.80*
  • With safety socket and test nipple
  • For easy testing of test objects
  • In plastic casing
Holder HTP06 Right

€389.60*
  • Side mounting for test waggon or table
  • Ergonomically placed
  • HV probe type: HTP
  • Side: right
  • Colour: white
Signal Lamp WK36SL-02

€289.30*
  • Devices: 36 series
  • Mounted on test trolley
  • Total hight of lamps 1850mm
  • Standard: EN 50191, VDE0104
  • Lights: Red/Green
  • Function: operation, switch on, ready
  • Cable length: 2m
Foot Switch 36 Cover

€251.80*
  • HV Tester: UB36, UG36, UH36, UX36
  • With foot protection cover
  • Start via control-IO
  • With plug: SUB-D 9-pole
  • Access to control interface
  • Cable length: 2m
Warning Sign WS-DHV "Danger High voltage!"

€23.50*
  • Rectangle design
  • "Danger High Voltage"
  • Material: plactic
  • Size: 74mm x 210mm
  • Colour: yellow/black
  • EN50191 / DIN 40008
.NET driver for Series 36 and Series 400

€170.00*
  • Drivers, example programs and programming manual
  • Functions: high-voltage test, protective earth test, insulation test, current consumption test, 2-wire/4-wire, user interface, external relay matrix
  • Compatible devices: UH36, UB36, UG36, RS36, MR36, ST400
HV Probe HTP06C-oS

€140.50*
  • HV test gun HTP06C with automatic start, contact check and cable break monitoring
  • HV cable, 2-pole, blue (D = 9.6 mm)
  • Without HV plug for plugging into the test instrument, open cable end
  • Max. operating voltages: 7 kV AC / 10 kV DC, max. 10 A