LCR Measuring Bridge ST2829A

Ordernr. 60944
EAN 4260254477065
€2,490.00
Excl. 16% VAT, excl. Shipping Cost
Only 2 left in stock

Frequently Bought Together

  1. LCR Measuring Bridge ST2829A
  2. +
  3. Measurement Software ST Meter Plus
  4. +
  5. Calibration LCR Meter 2016
Total price: €0.00

Details
Technical Service
+49 421 277 9999

Highlights

  • Test frequencies: 20Hz–300kHz
  • Resolution: 1mHz, 5-digit frequency input
  • Basic Accuracy 0.05%
  • Measuring Speed (f ≥10KHz): Fast: 9ms / Medium: 67ms / Slow 187ms
  • 150-point list sweep function
  • Scanning and graphical analysis based on frequency, AC level and DC bias
  • Built-in DC bias voltage source: 10V / 100mA
  • Independent DC voltage source: 10V / 50mA
  • Optional DC bias current source: 1A
  • USB, RS232, Handler, DCI, GPIB, LAN-LXI (option)

Specification

  • Measurement parameters: C, L, R, Z, Y, X, B, G, D, Q, θ, DCR, Δ% (Vdc-Idc)

AC Test Level Voltage:

  • 5mV–10Vrms
  • Resolution: 100µV, 3-digit input
  • Accuracy:
    • ALC ON: 10% x set current + 2mV
    • ALC OFF: 6% x set current + 2mV

AC Test Level Current:

  • 50µV–100mA
  • Resolution: 1µA, 3-digit input
  • Accuracy:
    • ALC ON: 10% x set current + 20 µA
    • ALC OFF: 6% x set current + 20 µA
  • Output impedance: 30Ω, 50Ω, 100Ω
  • Calibration function: open / short / load
  • Equivalent circuit: serial, parallel
  • Range mode: Auto and hold
  • Display mode: Direct reading, ΔABS, Δ%
  • Trigger Mode: Internal, manual, external, BUS
  • Internal DC bias voltage source:
    • Voltage/current range: 0V - ±10V / 0mA - ±100mA
    • Resolution: 0.5mV / 5µA
    • Voltage accuracy: 1% x set set voltage + 5mV
  • Optional: 1A Internal DC Bias current source ST9201
  • Suitable accessory: External DC Bias Current Source ST1778
  • Comparator function 10 bins and bin counters
  • Display: 800×480 LCD-display
  • Memory: 100 groups of control settings can be saved, 10 sets of gif images
  • Interface: USB DEVICE (USBTMC and USBCDC support), USB HOST (FAT16 and FAT32 support), RS232C, HANDLER
  • Power supply: Voltage: 99V−121V,198V−242V / Frequency: 47Hz−63Hz
  • Working Temperature & Humidity: 0°C − 40°C, ≤90%RH
  • Dimensions (W/H/D): 400/132/385 mm
  • Weight: 13kg
  • CE-conformity: EN 50 191

Measurement display ranges

|Z|, R, X, DCR: 0.00001Ω - 99.9999MΩ
|Y|, G, B: 0.00001nS - 99.9999S
L: 0.00001µ - 9.9999kH
C: 0.00001pF - 9.99999F
Q: 0.0001 - 99999
D: 0.00001 - 9.99999
θ(DEG): -179.999° - 179.999°
θ(RAD): -3.14159° - 3.14159°
Δ%: -999.999° - 999.999°

What's in the box

  • ST26011A Kelvin-Terminal-Test-Leads
  • ST26048 4-terminal test fixture
  • ST26010 Gilded shorting plate
  • Operation manual
  • Power cord
  • Factory calibration certificate

Specifications

Display 800xRGBx480 7-inch TFT LCD display
Frequency of test signal ST2829A 20Hz - 300kHz
ST2829B 20Hz - 500kHz
ST2829C 20Hz - 1MHz
Minimum resolution 1mHz, 5-digit frequency input
Accuracy 0.01%
AC Level Voltage range of test signal 5mV - 10Vrms
Minimum resolution of voltage 100µV, 3-digit input
Accuracy ALC ON 10% x set voltage + 2mV
ALC OFF 6% x set voltage + 2mV
Current range of test signal 50µA - 100mA
Minimum resolution of current 1µA, 3-digit input
Accuracy ALC ON 10% x set current + 20µA
ALC OFF 6% x set current+ 20µA
DC bias voltage source Voltage/Current range 0V - ±10V / 0mA - ±100mA
Resolution 0.5mV / 5µA
Voltage accuracy 1% x set voltage + 5mV
ISO ON Be used for the bias test of inductance and transformer
AC Source impedance ISO ON 100Ω
ISO OFF 30Ω, 50Ω 100Ω selectable
DCR Source impedance 30Ω, 50Ω, 100Ω selectable
DC Independent voltage source Voltage/Current range 0V - ±10V / 0mA - ±50mA
Resolution 0.5mV / 5µA
Voltage accuracy 1% x set voltage + 5mV
Output resistance 100Ω
Test parameters of LCR |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Parameter display of test page Two sets of main/sub parameters, the second set can be set as ON/OFF;
There can be 10 pages of list sweep with 15 points per page at most;
Multiple parameters continuous sweep graphical analysis.
Basic accuracy LCR test parameter 0.05%
Calibration conditions Warm-up time ≥ 30 seconds;
Environment temperature: 23±5°C;
Signal voltage: 0.3Vrms-1Vrms
Zeroing: After OPEN or SHORT;
Length of test cable: 0m
Measurement time (≥10 kHz) Fast: 9 ms / time
Medium: 67 ms / time
Slow: 187 ms / time
plus the refresh time of the characters on the display
Display range of LCR parameter |Z|, R, X, DCR 0.00001Ω - 99.9999MΩ
|Y|, G, B 0.00001µs - 99.9999s
C 0.00001pF - 9.99999F
L 0.00001µH - 99.9999kH
D 0.00001 - 99999.9
Q 0.00001 - 9.99999
θ(DEG) -179.999° - 179.999°
θ(RAD) -3.14159 - 3.14159
Δ% -999.999% - 999.999%
Equivalent circuit Serial, Parallel
Range mode Auto, Hold
Trigger mode Internal, Manual, External, Bus
Average times 1-256
Calibration function Open, short calibration with full frequency or dot frequency, Load calibration with standard test component
Math operation Direct reading, ΔABS, Δ%
Delay time setup 0-999, minimum resolution: 100µs
Comparator 10-bin sorting, BIN1-BIN9, NG, AUX
Bin counter
PASS/FAIL on front panel, LED indication
List sweep • There can be 10 pages of list sweep with 15 points per page at most.
• List sweep of frequency, AC voltage/ current, internal/external DC bias voltage/current and independent DC source voltage can be performed on each page. Each sweep point can be sorted separately.
Graphical analysis • Graph scanning and analysis of frequency, AC level, and DC bias can be performed.
•Set the sweep start point, end point and each sweep point.
• Display the maximum value, minimum value and show data of the chosen sweep point
• Scanning graphs can be stored into internal or external USB memory.
Internal nonvolatile memory 100 sets of LCRZ setting files 201 times test results 10 sets of GIF image, CSV data files
External USB memory • GIF image, CSV data files
• LCRZ setting files
• Test data can be stored via USB memory directly.
Interface 1A bias current source 1A DC bias current source (optional, ST2901) can be installed
I/O interface HANDLER on rear panel
SCI USB, RS232C
PCI GPIB (optional)
Memory interface USB HOST (front panel)
Bias current source control interface DCI External DC bias current source can be controlled by using DCI interface. The maximum bias current can reach 120A.
Standard configuration
General Specifications
Operating temperature and humidity 0°C - 40°C, ≤ 90%RH
Power supply Voltage 99V - 121V, 198V - 242V AC
Frequency 47Hz - 63Hz
Power Consumption Max. 80 VA
Dimension (WxHxD) 400mm x 132mm x 385mm
Weight Approx.13 kg