Hipot Tester ST9201B

Ordernr. 60372
EAN 4260254474033
€2,090.00
Excl. 19% VAT, excl. Shipping Cost
Only 2 left in stock

Frequently Bought Together

  1. Hipot Tester ST9201B
  2. +
  3. Calibration High Voltage tester
  4. +
  5. ST®EOL Fully automatic operating software
Total price: €0.00

Details
Technical Service
+49 421 277 9999

Highlights

  • AC withstanding voltage and insulation tester
  • 240×64 Dot-matrix graphic LCD display
  • Fast discharge and arc detection function
  • Body protection function
  • Built-in 8-channel matrix scanner for convenient use
  • Set voltage rising time, test time, and voltage dropping time
  • randomly for different load, DC withstanding voltage current
  • judging & waiting time
  • 100 test steps being stored per group, totally 50 groups, and the
  • total testing steps are limited at 500
  • Current base number correction function
  • RS-232C, Handler and SCAN Interface (optional)

Technical data

  • 8-channel matrix scanner (not for 9201, 9201B, 9201C)
  • Memory: 50groups, 100 steps per group, totally 500 steps
  • Voltage rise-time: 0.1s - 999s
  • Voltage fall-time: 0.1s - 999s
  • Voltage wait-time: 0.1s - 99.9s (only for DC) (not 9201)
  • Test time setting 0.3s - 999s
  • Interfaces: USB, RS232, HANDLER, REMOTE I/O, SCAN (optional)
  • Power supply: 230V / 50Hz
  • Dimensions (W/H/D) : 340/120/438.50 mm
  • Weight: 20kg
  • CE - conformity

Test methods

Withstanding voltage test

  • Output voltage
    - AC: 0.05kV — 5kV ± 1.0% of reading+5 digit, (50Hz ,60Hz optional)
    - DC: 0.05kV — 6kV ± 1.0% of reading+5 digit
    - Voltage adjustment rate: ≤ 1.0% +10V (rated power)
     
  • Current test range
    - AC: 0.1mA - 20mA
    - DC: 0.01mA - 5mA
    - Test accuracy ± 1.0% of reading + 5 digit
    - Discharge function: Discharge after test ends (DCW)

Insulation resistance test

  • Output voltage:
    - 0.05kV - 1kV ± (1.5% of reading + 5V)
  • Resistance test range:
    - 0.1MΩ - 10GΩ, (Current range within 10nA - 10mA)
  • Resistance test accuracy:
    - 500V-1000V 1MΩ - 1GΩ ±(5% of reading +5 digit) / 1GΩ - 10GΩ ±(10% of reading +5 digit)
    - 50V-500V 0.1MΩ - 1GΩ ±(10% of reading +5 digit)
  • Discharge function: Discharge after test ends

Arc detection

  • Measurement range:    
    - AC: 1mA - 15mA
    - DC: 1mA - 5mA         

What's in the box:

  • ST90001R HV connection cable with test clip
  • ST90001B HV Earth connection cable with test clip
  • ST90002 HV Test probe set
  • Factory calibration certificate
  • Power cord
  • User manual

Technical specification

Model ST9201 ST9201S ST9201B ST9201C

Output voltage

AC Voltage 0.05KV - 5KV
Frequency 50Hz, 60Hz selectable
Output power 150VA (5kV/30mA) 100VA (5kV/20mA)
DC Voltage 0.05KV - 6KV 0.5KV - 6KV -
Output power 50VA (5kV/10mA) 25VA (5kV/5mA) -
Discharge function Automatically after end of test -
IR Voltage 50V-1000V -
Output power 10 VA (1000V/10mA) -
Discharge function Automatically after end of test -
8 Channel Matrix - Yes -

Voltage indication

Range Range of voltage 0.00kV – 6.00kV AC/DC
Accuracy ±(1.0% of reading +2V)
Range AC 0.001mA – 30mA 0.001mA – 20mA
DC 0.1µA – 10mA 0.1µA – 5mA -
Accuracy ±(1% of reading +10digits) (after correction)
ARC AC 1mA – 15mA 1mA – 15mA
DC 1mA – 10mA 1mA – 5mA
Insulation resistance indication
Resistance measuring range 0.01MΩ– 9.99GΩ, (Strom: 10nA – 10mA) -
Accuracy ±(5% of reading + 5digits) -

General specification

Voltage rise-time 0.1s - 999s
Voltage fall-time 0.1s - 999s
Voltage wait-time (DC) 0.1s - 99.9s (only for DC)
Test time setting 0.3s - 999s
More features Fast charge, body protection function, handler, RS-232, GPIB interface, USB host for memory sticks