Microohmmeter MPK-203x

Ordernr. 60064
EAN 4260254470325
€3,735.00
Excl. 19% VAT, excl. Shipping Cost
Goods expected soon

Frequently Bought Together

  1. Microohmmeter MPK-203x
  2. +
  3. USB-Adapter ST20
  4. +
  5. Calibration Ohmmeter
Total price: €0.00

Details
Technical Service
+49 421 277 9999

Highlights

  • 200A high current Microohmmeter
  • Resistance measurement up to 20mΩ
  • Resolution: 0.1µΩ
  • Alphanumerical display
  • Direct reading up to 4½ digits
  • U/I (4-wires) measurement
  • Overheating protection
  • USB communications
  • Comfortable Control-Software ST®Meter (optional)
  • Internal memory for up to 200 readings
  • Built-in printer

Technical data

  • Test currents: 100A, 200A (True DC)
  • Basic accuracy: ± 0.5 % of reading ± 2 digits
  • Resolution: 0.1µΩ (R<200µΩ), 1µΩ (R<2000µΩ), 10µΩ (R<20mΩ)
  • Output voltage: 3.5Vdc (200A), 4.5 Vdc (100A), 5.8 Vdc (without load)
  • Maximum load resistance: 10mΩ (200A), 30mΩ (100A)
  • Measurement principle: Four-terminal, U/I
  • Protection of all sensitive components, avoiding any damage due to overheating
  • Built in memory for the storage of 200 tests readings
  • USB Interface
  • IP54 (with closed lid)
  • IEC 61010-1:1990
  • IEC 61010‑1:1992 amendment 2
  • Power supply: 220-240V AC
  • Operating temperature: -5°C to 50°C
  • Storage temperature: -25°C to 65°C
  • Humidity range: 95% RH (non condensing)
  • Weight: 11 kg
  • Dimensions (W/H/D): 502/394/190 mm

Measurement display ranges

Range

Current

0 - 19.99mΩ 100A
0 - 1999µΩ 200A

Differences of the 200A microohmmeter

MPK-204e

MPK203x

MPK215e

Is able to measure in the lower measuring range below 200A in battery operation. Above 200A mains connection is necessary 2 currents can be set. 100A and 200A Has an adjustable current from 5A to 200A
The measuring ranges can be switched analogously via the rotary wheel As a result, the measuring instrument can only be operated when connected to the mains. It is a completely digital measuring device. The setting can also be done with the numeric keypad.
It is possible to cover a measuring range up to 200 Ohm The measuring range goes up to 20mOhm Measuring range up to 1 Ohm
- It has an integrated memory for external communication. Internal memory with 50 registers and up to 80 measured values that can be stored.
- - Thus the device can also be controlled via software
- Has an integrated printer Up to 30 consecutive 1-minute measurements can be taken at 1-minute intervals

What's in the box

  • 2 Combined current and potential leads - up to 15 m
  • 1 Power cord
  • 1 Ground cable
  • 1 USB cable
  • 1 RS-232 cable
  • 1 Built-in thermal printer
  • 1 Case for the accessories
  • 1 License to use the software ST-Logger
  • 1 User guide
  • Accessories weight: Approx. 20.5 kg
  • Factory calibration

Options

  • Software ST®Logger
  • ST-20 USB-Serial-Adapter