Highlights

  • Ultra high measurement speed: 15ms (frequency≥100Hz)
  • 240×64 dot-matrix LCD display
  • Simple operation
  • 10 typical frequencies from 50Hz to 100kHz
  • Programmable test level from 10mVrms to 1.0Vrms
  • Constant voltage mode for multilayer ceramic capacitor (MLCC) measurement
  • Built-in DC bias voltage source from -5VDC to +5VDC or DC bias current source of max. 200mA
  • Accurate load correction
  • 5 selectable source impedance modes
  • List sweep function for up to 4 frequencies, signal levels and DC bias levels
  • Measurement signal V/I monitor function
  • Transformer parameter measurement function
  • Built-in 10-bin comparator, sorting and bin counter
  • Hi/Go/Low comparison function and beeper alarm
  • Key lock function
  • Automatic LCZ function
  • 10 sets of measurement parameters saved
  • Measurement parameters automatically loaded at the time of turning on instrument
  • Handler interface compatible with Agilent 4263B
  • IEEE-488 control command compatible with Agilent 4263B

Technical data

  • Parameter
    • LCR: |Z|,R, X, G, B, C, L, Q, D, θ(deg), θ(rad), DCR
    • Transformer: DCR2, M, Turns, N, 1/N, LA, LB
  • Basic accuracy: 0.1%
  • Equivalent circuit: Series, parallel
  • Mathematical function: ΔABS (absolute value deviation), Δ% (percent deviation)
  • Range mode: Auto, Hold, Manual conversion
  • Trigger mode: Internal, Manual, External, BUS
  • Measurement time: Fast: 20ms, medium: 60ms, slow: 295ms
  • Averageing: 1—255 measurements
  • Calibration function: Open, short, load correction
  • Measurement terminal: 5-terminal
  • List sweep: 4 frequencies, level, DC bias list sweep measurement
  • Display mode: Direct, ΔABS, Δ%, V/I (voltage/current monitor), bin No., and bin counter
  • Display 240×64 dot-matrix LCD display with resolution of 5 digits
  • Signal frequency: Total 10 points: 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz
  • Output impedance: 25Ω,100Ω, 25Ω/100Ω,C.V. (constant voltage)
  • Test level: 10mVrms—1.0Vrms, <200mV step 1mV, ≥200mV step 10mV
  • DC bias source: Fixed ±1.75VDC, 0~±5VDC adjustable; Resistance is 100Ω:±50mA Max; Resistance is 25Ω:±200mA Max
  • |Z|, R, X: 0.0001Ω — 99.999MΩ
  • G, B: 0.0001μS — 999.99S
  • C: 0.001pF — 1.9999F
  • L: 0.001μH — 99.99kH
  • D: 0.0001 — 9999
  • Q: 0.0001 — 99999
  • θ (DEG): -179.99º — 179.99°
  • θ (RAD): -3.1416 — 3.1416
  • Δ%: -99.999% — 999.999%
  • N,1/N: 0.001—999.99
  • DCR: 0.1 mΩ—199.99 kΩ
  • M,L2: 0.001 μH—99.99 kH
  • Files Comparator: 10 bins: 8 pass bins, 1 fail bin, 1 AUX bin
  • Comparator: HIGH/PASS/LOW
  • Memory: 12 sets of instrument settings saved and loaded
  • Interface: RS-232C, HANDLER, GPIB (option)
  • Operating temperature 0°C - 40°C
  • Operating humidity ⩽ 90%RH
  • Voltage: 99V - 242V
  • Frequency: 47.5Hz - 63Hz
  • Power consumption ⩽ 30VA
  • Dimensions (W×H×D): 350mm×120mmx425mm
  • Weight: Approx. 4.8 kg

What's in the box

  • ST26005A 4-terminal test fixture
  • ST26011A 4-terminal Kelvin test cable
  • ST26010 Gilded shorting plate
  • ST26038 transformer test fixture
  • Operation manual
  • Power cable
  • Factory calibration