Drive Technology
Find your ideal drive solution. Sourcetronic is available in a range from 0.4 KW up to 630 KW, with frequency inverters, pump control, emi filters, breaking resistors, softstarters, chokes, software and apps.
- Power: 16.0 KW
- Resistance: 4 Ohm
- Max. current carrying capacity: 80A
- Voltage: <800V
- Temperature contact
- Terminal: M6
- Dimensions (W/H/D): 410.5/685/142mm
- Weight: 30.8kg
- RoHS compliant
- CE compliant
- Protection class: IP20 (EN 60529)
- Temperature coefficient: <400ppm/C°
- Resistance material: 0Cr25AL
- Power: 20 KW
- Resistance: 4 Ohm
- Max. current carrying capacity: 80A
- Voltage: <800V
- Temperature contact
- Terminal: M6
- Dimensions (W/H/D): 410.5/685/142mm
- Weight: 34.4kg
- RoHS compliant
- CE compliant
- Protection class: IP20 (EN 60529)
- Temperature coefficient: <400ppm/C°
- Resistance material: 0Cr25AL
- Start braking voltage (V): 670
- Maximum continuous braking current (A): 15
- Peak current (A): 50
- Protection: short circuit, overheating, over- and undervoltage
- RoHS compliant
- CE compliant
- Start braking voltage (V): 670
- Maximum continuous braking current (A): 25
- Peak current (A): 75
- Protection: short circuit, overheating, over- and undervoltage
- RoHS compliant
- CE compliant
- IP20 protection
- Current: 7 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 16 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 30 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 42 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 50 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 65 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 80 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 110 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- IP20 protection
- Current: 150 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation