Highlights

  • Test frequency: 20 Hz - 500 kHz
  • Accuracy: 0.05%
  • Resolution: 10 mHz
  • 4.3" LCD-Display
  • Resistance selectable: 30Ω / 50Ω / 100Ω
  • Internal DC Bias source and list-sweep function
  • LAN-LXI, RS232C, Handler, USB, GPIB (optional)

Specifications

  • Test Parameters: |Z|, |Y|, C, L, X, B, R, G, D, Q, θ(DEG), θ(RAD), DCR, Δ
  • Transformer Test Parameters: DCR1, DCR2, M, N, 1/N, Phase, La, Lb, Lk, C, balance test

AC voltage Test Level:

  • 10mV–2Vrms
  • Resolution: 100µV, 3-digit input
  • Accuracy:
    • ALC ON: 10% x Voltage + 2mV
    • ALC OFF: 6% x Voltage + 2mV

AC current Test Level:

  • 100µA–20mA
  • Resolution: 1µA, 3-digit input
  • Accuracy:
    • ALC ON: 10% x Strom + 20 µA
    • ALC OFF: 6% x Strom + 20 µA
  • Measurement time (≥ 10kHz): Fast: 13ms / Medium: 67ms / Slow 187ms
  • 10-point list sweep function
  • Test signal function
  • Internal DC BIAS source:
    • Voltage/current range: 0V - ±5V / 0mA - ±50mA
    • Resolution: 0.5mV / 5µA
    • Accuracy: 1% x Voltage + 5mV
  • Equivalent circuit: serial and parallel
  • Range mode: Auto and Hold
  • Trigger Mode: internal, external, manual and BUS
  • Average times: 1-255
  • Comparator: 0-bin and counter
  • Calibration function: open, short, load
  • Power supply: 99 - 121V, 198V-242V / 47/63 Hz
  • Temperature / humidity: 0°C - 40°C, ≤ 90% RH
  • Dimension (W/H/D): 369/108/408 mm
  • Weight: 5 kg
  • CE-conformity: EN 50 191

Measurement range

|Z|, R, X, DCR: 0.00001Ω - 99.9999MΩ
|Y|, G, B: 0.00001nS - 99.9999S
L: 0.00001µ - 9.9999kH
C: 0.00001pF - 9.99999F
Q: 0.0001 - 99999
D: 0.00001 - 9.99999
θ: -179.999° - 179.999°
θ(RAD): -3.14159° - 3.14159°
Δ%: -999.999° - 999.999°

What's in the box

  • ST26048 4 terminal test fixture
  • ST26011A 4 terminal Kelvin test clip leads
  • ST26010 Gilded shorting plate
  • ST26038 Transformer test fixture
  • ST26004B Kelvin Test Clips (2x)
  • Operation manual
  • Power cable
  • Factory calibration certificate

Specifications

Display 800xRGBx480 7-inch TFT LCD display
Frequency of test signal ST2827A 20Hz - 300kHz
ST2827B 20Hz - 500kHz
ST2827C 20Hz - 1MHz
Minimum resolution 10mHz, 4-digit frequency input
Accuracy 0.01%
AC Level Voltage range of test signal 10mV - 2Vrms
Minimum resolution of voltage 100µV, 3-digit input
Accuracy ALC ON 10% x set voltage + 2mV
ALC OFF 6% x set voltage + 2mV
Current range of test signal 100µA - 20mA
Minimum resolution of current 1µA, 3-digit input
Accuracy ALC ON 10% x set current + 20µA
ALC OFF 6% x set current + 20µA
DC bias voltage source Voltage/Current range 0V - ±5V / 0mA - ±50mA
Resolution 0.5mV / 5µA
Voltage accuracy 1% x set voltage + 5mV
ISO ON Be used for the bias test of inductance and transformer
AC Source impedance ISO ON 100Ω
ISO OFF 30Ω, 50Ω 100Ω selectable
DCR Source impedance 30Ω, 50Ω, 100Ω selectable
Test parameters of LCR |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Parameter display of test page One set of main/sub parameter, 10-point list sweep
Test parameters of transformer DCR1 (primary, 2-terminal), DCR2 (secondary, 2-terminal), M (mutual inductance), N, 1/N, Phase, La/Lb (primary, secondary inductance), Lk (leakage inductance), C (primary, secondary capacitance), balance test
Basic accuracy LCR test parameter 0.05%
N 0.1%
Calibration conditions Warm-up time ≥ 30 seconds; Environment temperature: 23±5°C; Signal voltage: 0.3Vrms-1Vrms Zeroing: After OPEN or SHORT; Length of test cable: 0m
Measurement time (≥10 kHz) Fast: 13 ms / time
Medium: 67 ms / time
Slow: 187 ms / time
plus the refresh time of display character
Display range of LCR parameters |Z|, R, X, DCR 0.00001Ω - 99.9999MΩ
|Y|,G, B 0.00001µs - 99.9999s
C 0.00001pF - 9.99999F
L 0.00001µH - 99.9999kH
D 0.00001 - 99999.9
Q 0.00001 - 9.99999
θ(DEG) -179.999° - 179.999°
θ(RAD) -3.14159 - 3.14159
Δ% -999.999% - 999.999%
Equivalent circuit Serial, Parallel
Range mode Auto, Hold
Trigger mode Internal, Manual, External, Bus
Average times 1-255
Calibration function Open and short calibration with full frequency or dot frequency, Load calibration with standard test component
Math operation Direct reading, ΔABS, Δ%
Delay time setup 0-999, minimum resolution: 100µs
Comparator 10-bin sorting, BIN1-BIN9, NG, AUX
Bin counter
PASS/FAIL on f ront panel , LED indication
List sweep • 10 points list sweep
• Frequency, AC voltage/current, internal/external bias voltage/ current can be swept.
• Each sweep point can be sorted separately.
Internal nonvolatile memory 100 sets of LCRZ setting files
201 times test results
External USB memory • GIF images
• LCRZ setting files
• Test data can be stored via USB memory directly.
Interface I/O interface HANDLER on rear panel
SCI USB, RS232C
PCI GPIB (optional)
NI LAN-LXI
Memory interface USB HOST(front panel)
Bias current source control interface DCI External DC bias current source can be controlled by using DCI interface. The maximum bias current can reach 120A.
Option: Only choose either DCI or GPIB
General Specifications
Operating temperature and humidity 0°C - 40°C, ≤ 90%RH
Power supply Voltage 99V - 121V, 198V - 242V AC
Frequency 47Hz - 63Hz
Consumption Max. 80 VA
Dimension(WxHxD) 280 mm x 88 mm x 370 mm (without sheath) 369 mm x 108 mm x 408 mm (with sheath)
Weight Approx.5 kg