Highlights
- Input Frequency Range: 50 Hz / 60 Hz ( ± 5%)
 - Output Frequency Range: 0 Hz - 599 Hz
 - Voltage: 380 V(-15%) – 480 V(+10%)
 - Side-by-side Mounting: Compact design requiring minimal space, easy installation in tight spaces
 - Top Entry: Optimal integration into a control cabinet with top entry
 - Push-in Terminals: Control wiring terminals are push-in terminals, allowing for easy connection
 - Shield Mounting Plates: Shielded cables can be mounted EMC compliantly on the top and bottom
 - STO: Every ST300 series frequency inverter features the STO safety function (SIL3, PLe)
 - German User Manual: A highly detailed German user manual is available for free download
 - First-class technical support from experts, comprehensive user manual, and helpful FAQs
 - Integrated C3 filter, higher level possible simply via external filters
 - Modbus RTU: The frequency inverter features an RS485 interface with Modbus RTU standard
 - Adjustment options: Over 40 digital input functions, over 20 digital output functions, and over 20 analog output functions
 
Scope of Delivery
- ST300 Frequency Inverter
 - Shield Plate A/B/C
 
Technical Specifications
                Network Properties | 
        |
| Input Voltage: | AC 3~ 380V (-15%) to 480V (+10%) | 
| Rated Power: | 0.75 - 7.5 kW | 
| Input Rated Current (at 380V): | 4.5 - 28.7 A | 
| Input Frequency: | 50Hz or 60Hz ±5%, with a maximum change rate of 20%/s | 
| Integrated EMC Filter Class: | C3 | 
                Motor Connection Data | 
        |
| Control Modes | V/f Characteristic / Open Loop Vector Control | 
| Output Voltage: | 0 - 100% of Supply Voltage | 
| Output Current: | 2.5 - 18.5 A | 
| Output Frequency: | 0 - 599Hz | 
| Ramp Times: | 0.0 - 3600.0s | 
| Ramp Functions: | Linear / S-Curve | 
| Overload Function: | 150% for one minute 180% for 10 seconds  | 
        
| Carrier Frequency: | 1kHz - 15kHz adjustable | 
| V/f Curve Modes: | Linear / Quadratic / Adjustable | 
| Braking Unit: | Integrated (external braking resistor possible) | 
| Type of Motor: | Asynchronous Induction Motor or Permanent Magnet Synchronous Motor | 
Digital Inputs | 
        |
| Programmable Digital Inputs: | 6, of which 4x max. 1kHz (S1-S4), 1x max. 50kHz (HDIA) with 42 input functions  | 
        
| Voltage Level: | 0 - 24VDC | 
| Logic: | NPN (active when input is connected to GND) | 
| Maximum Voltage at Input: | 30VDC | 
| Number of Programmable Pulse Inputs: | 1 (HDIA) | 
| Maximum Input Frequency: | 50kHz, duty cycle 30 to 70% | 
| Resolution for Frequency Control: | 0.1% | 
| Safety STO: | Redundant inputs for connection to +24V via NC contacts for the safety function STO (immediate interruption of power supply to the drive when at least one of the connections to +24V is interrupted). Factory connected to +24V via shorting links (STO inactive). | 
Digital Outputs | 
        |
| Programmable Outputs: | 1 Open-Collector output, max. 1kHz | 
| Voltage Level: | 24VDC, max. 30VDC, 50mA | 
| Logic: | NPN (output is active against GND) | 
| Minimum Output Frequency: | 0Hz | 
| Maximum Output Frequency: | 1kHz | 
| Number of Functions: | 25 | 
Relay Outputs | 
        |
| Programmable Outputs: | 1 | 
| Terminal Number: | RO1A: NO; RO1B: NC; RO1C: Common (Root Contact) | 
| Maximum Power AC: | 250VAC / 3A | 
| Maximum Power DC: | 30VDC / 1A | 
| Number of Functions: | 26 | 
Analog Inputs | 
        |
| Number of Analog Inputs: | 2 | 
| Type of Inputs: | AI 1: 0-10V / 0(4)-20mA  AI 2: -10 to +10V  | 
        
| Resolution for Frequency Control: | max. frequency * 0.05%, tolerance ±0.5%@25°C | 
Analog Outputs | 
        |
| Programmable Outputs: | 1 | 
| Voltage Range: | 0 - 10VDC max. 5mA | 
| Current Range: | 0(4) - 20mA | 
| Number of Functions: | 23 | 
Communication | 
        |
| RS485 (RTU) | Integrated | 
Dimensions, Weight | 
        |
                 
             | 
        |
| Dimensions W1 x H1 x D1 (W x H x D)  | 
            60 - 90mm x 190 - 235mm x 155mm | 
| Mounting Hole Spacing | W2 = 36 - 70mm H2 = 180 - 220mm  | 
        
| Mounting Hole Diameter | 5 - 6 mm | 
| Net Weight: | 0.99 - 1.95 kg | 
Environmental Requirements | 
        |
| Operating Environment Temperature: | -10°C to 50°C: no derating required; Note: Derating becomes necessary when the ambient temperature exceeds 50°C. For further details, see the operating manual | 
| Protection Class: | IP20 | 
| Altitude: | Lower than 1000m, when exceeding 1000m, reduce the power by 1% per 100m altitude. | 
| Vibration: | Max. Vibration ACC: 5.8m/s2 (0.6g) | 
| Installation Direction: | Vertical | 
| Relative Humidity (RH) | <90% | 
Standards | 
        |
| EN/ISO 13849-1 | Safety of Machinery – Safety-Related Parts of Control Systems Part 1: General Principles for Design  | 
        
| EN/ISO 13849-2 | Safety of Machinery – Safety-Related Parts of Control Systems Part 2: Validation  | 
        
| IEC/EN 60204-1 | Safety of Machinery – Electrical Equipment of Machines Part 1: General Requirements  | 
        
| IEC/EN 62061 | Safety of Machinery – Functional Safety of Electrical, Electronic, and Programmable Electronic Control Systems | 
| IEC 61800-3:2018 | Adjustable Speed Electrical Power Drive Systems Part 3: EMC Requirements and Specific Test Methods  | 
        
| IEC/EN 61800-5-1 | Adjustable Speed Electrical Power Drive Systems Part 5-1: Safety Requirements – Electrical, Thermal, and Energy  | 
        
| IEC/EN 61800-5-2 | Adjustable Speed Electrical Power Drive Systems Part 5-2: Safety Requirements – Function  | 
        
- NL - ST300 Verkorte Handleiding (1.04 MB)
 - EN - ST300 Quick Start Guide (26.3 MB)
 - EN - ST300 User Manual (37.78 MB)
 - DE - ST300 Bedienungsanleitung (15.78 MB)
 - PL - ST300 Skrócony Podręcznik (836.37 KB)
 - IT - ST300 Manuale Sintetico (1025.55 KB)
 - DK - ST300 Forkortet Manual (835.15 KB)
 - DE - ST300 Quick Start Guide (26.3 MB)
 - ES - ST300 Manual Abreviado (813.98 KB)
 - FR - ST300 Manuel Abrégé (802.98 KB)
 - DE - ST300 Kurzanleitung (1.82 MB)
 
Accessoires
- Devices: ST300 (Beta) / ST500 / ST600 series
 - Clear parameter structure
 - Easy changing of parameters
 - Parameters can be saved on the PC and printed out via a printer
 - Saved parameter files can be reloaded as a backup
 - Communication via USB-RS485 adapter cable
 
- Telefonische Beratung
 - Auslegung und Inbetriebnahme
 - Individuelle Parametrierung
 - Programmbetrieb
 - Parameterliste
 
- Large shield mounting for motor cables
 - Simple and efficient shielding connection
 - Suitable for ST300 frequency inverters up to 4 kW
 
- IP20 protection
 - Current: 7 A (nominal current must be greater than the input current of the frequency inverter)
 - Voltage: 400 V
 - Category: C2
 - Reduces Voltagepeaks
 - Attenuates electromagnetic radiation
 
- Resistance: 400 Ω
 - Rated power: 300 W (continuous braking power with appropriate heat dissipation)
 - Operating voltage range: up to 400 V
 - IP Grade: IP00/IP33
 - Weather resistant and vibration resistant
 - Easy insatallation
 
- Rated voltage: 3 x 400 Vac
 - Rated voltage (IEC): 3 x 690 Vac
 - Rated voltage (UL): 3 x 600 Vac
 - Short circuit voltage uK: 4 % @ 400 Vac
 - Voltage drop: 9,2 Vac @ 400 Vac
 - Rated current: 3 x 6 A
 - Rated frequency: 50 - 60 Hz
 - Inductance: 4,900 mH
 - Inductance deviation: ±10 %
 
- Rated voltage: 3x 400 Vac
 - Voltage range: 3 x 0 - 500 Vac
 - Rated current: 2,5 A
 - for motor rated output approx. 0,75 kW
 - Inductance: 2,550 mH
 - Rated frequency: 0 - 50 Hz
 - Switching frequency: 3 - 8 kHz
 
- Rated voltage: 3 x 400 Vac
 - Voltage range: 0 - 520 Vac
 - Voltage drop: 7,5% @ 400
 - Rated current: 4A
 - for motor rated output approx. 1,5 kW
 - Rated frequency: 0 - 150 Hz
 - Switching frequency: 4 - 8 kHz
 
- Price per meter
 - Number of cores and mm² per conductor: 4G1.5 (3x 1.5mm² black and 1x 1.5 mm² PE)
 - Outer diameter in mm: 11.4
 - Connecting cable for electric drives with high output
 - EMC optimized and double shielded
 - 3 + 3 symmetry reduces common mode interference