Electrical Safety Tester ST400 (Rental device)

Ordernr. 61870
EAN 4260409221444
€449.00
Excl. 16% VAT, excl. Shipping Cost
Goods expected soon
Details
Technical Service
+49 421 277 9999

This article is also in our shop available

Highlights

  • AC / DC EST Electrical Safety Tester
  • Brilliant 320x240 Colour-Touchscreen
  • DLL, ActiveX, LabView drivers
  • Quality control plan editor
  • Switch on relay matrix
  • Safety current limited - No barriers
  • Test standards: EN60065 / VDE 0860, EN 60598 / VDE 0710, EN60335 / VDE 0686 / EN 50106, EN60601 / VDE 0750, EN 60950 / VDE 0805, and many more
  • PLC, RS232, CAN
  • GOOD-/ FAIL-display
  • Dynamic memory management for test programs

Test steps

  • Continuity and short-circuit test
    • 0-25 VAC / 0-100 Ohm
    • Thresholds up to 0.6 A
    • Electronically controlled
    • Adjustable Current Limit
  • PE test
    • Test 2 to 25 AAC
    • Open circuit voltage 6 V or 12 V
    • Resistance measurement up to 500 mOhm
    • Fully electronic AC power source
    • 4-wire technology
  • Insulation test
    • Voltage programmable: 50 VDC to 500 VDC
    • Measuring range 0 - 400 MOhm
    • Testing on interface or testing gun
    • Safety current limited in accordance with EN50191
    • Ramping with active discharge
  • High-voltage test DC
    • Programmable voltage of 100 VDC to 3000 VDC
    • Tripping current 0.001 - 2 mA
    • Test on socket or test probe
    • Safety current limited in accordance with EN50191
  • Function test
    • External power feeding up. 270 VAC / 10 A (1-phase)
    • Power consumption test, single-phase 0.01 to 10 AAC
    • For 50/60 Hz/li>

General

  • Button: GOOD, BAD START, safety circuit
  • LED indicators: GOOD, BAD, operation, safety
  • Keylock, remote, error
  • Main switch illuminated pushbutton
  • Function rotary switch "Navigation Plus"
  • Interfaces / Ports:
    • Controllable test process via PLC
    • I / O interface for relay matrix
    • ADF interface for analog and I / O frequency inputs
    • RS232, CAN, USB / LAN optional
    • HV connectors (2 pin)
    • PE test probe
    • SHK safety circuit (8 pin)
    • WK400 warning light connection
    • Redundant grounding PE
  • Freely programmable device including all limits
  • Operating modes: manual, digital, automatic, Ethernet
  • Visual and audible alarm
  • Auto Start function
  • Internal clock / calendar
  • Base period 0.1 ... 999.9 sec
  • discharge of the DUT
  • Passwords for the program, menu, service, macros
  • Supply 90 V - 250 V, 50 Hz / 60 Hz
  • Weight approximately 18 kg

What's in the Box

  • Mating connector for external power supply
  • Power cord
  • User manual
  • Test report