Hipot Tester ZPA-ADC-3550-0100-OGW

Ordernr. 60998
EAN 4260254477676

Price on request

Goods expected soon
Details
Technical Service
+49 421 277 9999

Hipot Tester ZPA-ADC-3550-0100-OGW

Two-part high-voltage AC test system for testing the voltage resistance. The connection is made via high voltage cables to the test object. The system consists of a separate control unit (control unit) and a power unit. The voltage drop occurs on the power section via a tube which has been shown above. The power unit of the test unit is housed in a mobile metal housing. The housing is equipped with large rubber tires (160 mm). The control unit can be fixed for transport on the power section.

Highlights

  • 35000V AC and 50000V DC (selectable)
  • Ramping
  • Robust burning function
  • With oil transformer
  • 4-wire-contact monitoring
  • Wire break monitoring
  • Launch control
  • Programmable test parameters
  • RS232, digital I/O (SPS), CAN
  • Software, DLL, LabView, Active-X (option)

Test methods

High voltage test AC

  • AC voltage: 1000 V - 35000 V
  • AC current: 0.5 - 100 mA
  • Short circuit current: > 200 mA
  • Transformer capacity: 2000 VA
  • Output frequency 50 Hz / 60 Hz

High voltage test DC

  • DC voltage: 1000 V - 50000 V
  • DC current: 0.5 - 70 mA
  • Short circuit current > 200 mA
  • Transformer power: 2000VA

Technical data

  • Desktop unit with oil transformer
  • Regulated test voltage
  • High voltage output via tube
  • Error message: acoustic, optical, interface
  • Zero voltage switch(to conserve test object)
  • ACTUAL- and SET POINT-display (current/voltage)
  • Keyboard lock
  • Acoustic signaling adjustable
  • Display brightness control
  • Start mode selectable
  • Data management program with your PC (optional)
  • Ramp times and ramp types
  • Verifying time scaling
  • Test time: 1-99s / 1-99 minutes and infinitely
  • Minimum current monitoring
  • Integrated program memory
  • Large LED display and various control buttons
  • CAN bus for expansions
  • Digital I/O:
    • START / STOP
    • PASS / FAIL
    • Test in progress
  • Terminals:
    • 2 HV sockets potential free
    • Warning lamp
    • Foot switch, test-cage, light curtain, prod.-line, two-hand-operation
  • Highest safety standard:
    • Key switch preventing unauthorized use
    • High voltage absolutely potential-free
    • Two fold isolated transformer and measurement converter
    • Status indication
    • Socket for external pilot lamp
    • Integrated warning buzzer
    • Insulated sockets
    • Security activation knob in compliance with VDE0104
    • Safety Circuit with forcibly actuated HV relays
  • Power supply: 400V, 50/60 Hz
  • Mains connection: CEE 32 A, 5p
  • Tolerance input voltage: +/- 10 %
  • Current consumption: max. 25A
  • Fuse: B 32 A
  • Mains connection: schuko plug
  • Tolerances: ± 10%
  • Operating temperature: +5° to +40°
  • Humidity: 80% (non condensing)
  • Casing: IP20
  • Compact industrial housing (RAL 7035)
  • Weight: 370 kg
  • CE-conformity, according to EN 50 191
  • Cooling: passive, active cooling optional available

Dimensions

  • Width test trolley/body (corpus): 610 mm
  • Width test trolley incl. handle: 770 mm
  • Width test trolley incl. handle and wire holder: 830 mm
  • Hight test trolley incl. castor: 250 mm
  • Hight test trolley incl. castor and tube: 700 mm
  • Depht test trolley/body (corpus): 650 mm
  • Depht test trolley incl. handle: 750 mm
  • Depht test trolley incl. handle: 1240 mm

What's in the box

  • Interlock connector
  • Key set
  • Power cable
  • Operation manual
  • Factory calibration