ST130 | Error E.oC1 – What does it mean and what can be done?

If the error message E.oC1 appears on the ST130 inverter display, it indicates an overcurrent fault during acceleration of the connected motor.

Possible cause Possible solution
Acceleration ramp too short Increase the acceleration time (F0.05)
Manual torque boost
or unsuitable V/f curve
Reduce torque boost or adjust V/f curve
Supply voltage too low Check mains connection
Short circuit at motor Inspect motor wiring
Missing or incorrect motor parameters Enter correct motor data
Motor already moving before start Enable speed detection or stop motor before starting
Phase loss at inverter output Check output wiring
Inverter power rating too low Use a higher-rated inverter