Certyfikowany system zarządzania jakością
LCR Measuring Bridge ST2829C
5 690,00 €*
Szczegóły
+49 421 277 9999
Informacje o produkcie "LCR Measuring Bridge ST2829C"
Highlights
- Test frequencies: 20Hz–1MHz
- Resolution: 1mHz, 5-digit frequency input
- Basic Accuracy 0.05%
- Measuring Speed (f ≥10KHz): Fast: 9ms / Medium: 67ms / Slow 187ms
- 150-point list sweep function
- Scanning and graphical analysis based on frequency, AC level and DC bias
- Built-in DC bias voltage source: 10V / 100mA
- Independent DC voltage source: 10V / 50mA
- Optional DC bias current source: 1A
- USB, RS232, Handler, DCI, LAN-LXI, GPIB (option)

Specification
- Measurement parameters: C, L, R, Z, Y, X, B, G, D, Q, θ, DCR, Δ% (Vdc-Idc)
AC Test Level Voltage:
- 5mV–10Vrms
- Resolution: 100µV, 3-digit input
- Accuracy:
- ALC ON: 10% x set current + 2mV
- ALC OFF: 6% x set current + 2mV
AC Test Level Current:
- 50µV–100mA
- Resolution: 1µA, 3-digit input
- Accuracy:
- ALC ON: 10% x set current + 20 µA
- ALC OFF: 6% x set current + 20 µA
- Output impedance: 30Ω, 50Ω, 100Ω
- Calibration function: open / short / load
- Equivalent circuit: serial, parallel
- Range mode: Auto and hold
- Display mode: Direct reading, ΔABS, Δ%
- Trigger Mode: Internal, manual, external, BUS
- Internal DC bias voltage source:
- Voltage/current range: 0V - ±10V / 0mA - ±100mA
- Resolution: 0.5mV / 5µA
- Voltage accuracy: 1% x set set voltage + 5mV
- Optional: 1A Internal DC Bias current source ST9201
- Suitable accessory: External DC Bias Current Source ST1778
- Comparator function 10 bins and bin counters
- Display: 800×480 LCD-display
- Memory: 100 groups of control settings can be saved, 10 sets of gif images
- Interface: USB DEVICE (USBTMC and USBCDC support), USB HOST (FAT16 and FAT32 support), RS232C, HANDLER
- Power supply: Voltage: 99V−121V,198V−242V / Frequency: 47Hz−63Hz
- Working Temperature & Humidity: 0°C − 40°C, ≤90%RH
- Dimensions (W/H/D): 400/132/385 mm
- Weight: 13kg
- CE-conformity: EN 50 191
Measurement display ranges
| |Z|, R, X, DCR: | 0.00001Ω - 99.9999MΩ |
| |Y|, G, B: | 0.00001nS - 99.9999S |
| L: | 0.00001µ - 9.9999kH |
| C: | 0.00001pF - 9.99999F |
| Q: | 0.0001 - 99999 |
| D: | 0.00001 - 9.99999 |
| θ(DEG): | -179.999° - 179.999° |
| θ(RAD): | -3.14159° - 3.14159° |
| Δ%: | -999.999° - 999.999° |
What's in the box
- ST26011B Kelvin-Terminal-Test-Leads
- ST26048 4-terminal test fixture
- ST26010 Gilded shorting plate
- Operation manual
- Power cord
- EN - ST2829 User Manual (4.55 MB)
- EN - ST2829C Handler (919.16 KB)
- DE - ST2829 Bedienungsanleitung (4.96 MB)
Related products
- Standard-compliant, multi-vendor calibration based onISO 17025
- Measuring devices: VDE devices, LCR meter, safety tester, bridges, ...
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Plug & Play Ansteuerung für Sourcetronic LCR Messgeräte
- Komplette Fernsteuerung der Messgeräte
- Komfortable Oberfläche im JAVA "look&feel"
- Automatisch skalierende graphische Kurven-Verläufe
- Linear & logarithmisch
- Extra "Live"-Daten Fenster
- Automatische Nullkalibrierung Short / Open
- Spezialfunktion "Frequency Sweep in graphischer Darstellung
- Benutzerdefinierbarer Grenzwertvergleich
- Robust 19" mounting frame
- Metal powder coated
- Device mounting front
- Devices: ST2829, ST2829XX, ST2883
- Color: RAL7035 light gray
- Height: 4 HE
- Devices: ST2829A/-B/-C, ST2829AX /-BX /-CX
- Extension of DC bias
- Current: ±1 A DC
- Extension of GPIB interface
- For hipot tester,
Impedanz analyzer, ohmmeter,
LCR meter, multimeter
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- 4-wire technology
- Kelvin-leads with BNC-Terminal
- Isolation of soft PVC
- Multi colored cable (red and black)
- Strain relief and bend protection
- Frequency up to 5MHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagentic parts
- Can be used with commercial LCR bridges
- DC Bias Current Source: 0A up to 120A
- Output voltage 0 - 35V
- Frequency bandwidth: 50Hz - 200Hz
- Accuracy: 1%
- Resolution up to: 5mA
- For wide range of LCR Meter
- Connection cable GPIB
- IEEE 488.2, 24 pin
- LCR meter, milliohm meter, multimeter
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- Golden shorting plate
- Measuring device zero claibration
- For all LCR test fixture
- Devices: LCR Meter ST2827A/C, ST2829A/C
- Robust transport case
- Aluminium frame lid can be opened
- Equipment compartment with punctual foam lining
- Clearly arranged accessory compartments
- Highest transport safety
- 2 central butterfly locks at the front
- 2 locking hinges at the rear
- 1 HighEnd case handle at the front
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters