Back to the homepage
Main page » Catalogue » LCR Meter » Precision LCR Meter ST2818
 Search
 Informations
Ordering InformationCompanySolutionsService

Precision LCR Meter ST2818

Precision LCR Meter ST2818
  • Auto balancing bridge method with widest impedance range
  • 4-terminal pair configuration
  • Basic accuracy: 0.05 %
  • Testfrequency: 300 kHz
  • AC test signal programmable to 20 V (optional)
  • Measurement speed up to 30 meas/sec.
  • 6-digit display resolution
  • 22 parameter combinations available
  • Output impedance: 30Ω and 100Ω selectable
  • 10 point list sweep function
  • Sweep analysis function with 960 points
  • Internal DC bias source ± 40V/100mA (optional)
  • External DC bias 40A (optional)
  • Automatic level control function (ALC)
  • Test signal level monitor function
  • 20 control settings files can be saved in internal memory
  • Built-in comparator: 10 bins and bin counters
  • RS232C, Handler, GPIB (option)
  • 2m / 4m cable length extension
  • USB interface for external memory of set data
  • 320 x 240 dot matrix large-graphic LCD display

Specifications 

Measurement functions

|Z|, R, X: 0.01
- 99.9999
|Y|, G, B: 0.01 nS - 99.9999 S
L: 0.01 nH - 99.9999 kH
C: 0.01 pF - 9.99999 F
Q: 0.00001   - 99999.9  
 D: 0.00001   - 9.99999  
θ (DEG):
-179.999
°
 - 179.999
°
θ (RAD):
 -3.14159   -
3.14159
 
Turns-Ratio: 1:0.01   - 100:1  
∆%: -999.999 % - 999.999 %

     

  • Test parameter: |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, ESR, Rp (equivalent parallel resistance)
  • 22 parameter combinations available
  • Equivalents circuit: series, parallel
  • Math function: deviation and percent deviation
  • Range mode: auto, hold, manual
  • Range subsection (9 sects: 10Ω, 30Ω, 100Ω, 300Ω, 1kΩ, 3kΩ, 30kΩ, 100kΩ
  • Trigger Mode: internal, manual, external, BUS
  • Measuring time (≥1kHz.): fast 32ms,  med 90ms, slow 650ms
  • Average rate: 1-255
  • Delay time: 0 - 60 s, with step of 1 ms
  • Calibration function: Open/Short frequency pint, full frequency correction, load correction
  • Measurement terminal: 4 terminal pair
  • Test cable length: Standard (0m, 1m), Option (2m, 4m)
  • Display mode: direct, ∆, ∆%, bin No, bin counter, list sweep, V/I (voltage/current monitor)
  • Display: 320 x 204 dot-matrix graphic LCD display

Test signal

  • Frequency: 20 Hz - 300 kHz
  • Resulution 10mHz
  • Accuracy 0,01%
  • Test level range: regular 5 mV to 2 V, Turn-ratio: 5 mV to 4 V (accuracy: 5%, resolution: 1mV) 
  • Output impedance: 30 Ω and 100 Ωselectable

Measurement signal mode

  • Normal: voltage or current program selectable at the measurement terminals when they are opened or shorted, respectively
  • Constant level: Maintain selected voltage or current value at the DUT independent of component impedance change

AC measurement level signal

  • Standard:
    Normal V:  5mVrms - 2Vrms  /  Normal I:  50μArms - 20mArms
    Constant level V:  10mVrms - 1Vrms  /  Constant level I:  100μArms - 10mArms
  • Option ST10301:
    Normal V:  5mVrms - 20Vrms  /  Normal I:  50μArms - 200mArms
    Constant V:   10mVrms - 10Vrms  /  Constant I:  100μArms - 100mArms

DC bias

  • Standard: 0V, 1.5V, 2V DC
  • ST10301 (option):
    ±0.000 - 4.000 VDC, 1mV resolution
    ±4.002 - 8.000 VDC, 2mV resolution
    ±8.005 - 20.000 VDC, 5mV resolution

Other functions

  • List sweep function: 10 frequency or test signal level points can be swept. Single or continuous test mode can be performed. When Option 001 is installed, DC bias level points can also be swept.
  • Comparator: 10-bin sorting and bin counter for measurement parameters, IN/OUT judgement for sub parameters
  • Bin counter: 0 - 999999
  • List sweep comparator: HIGH/IN/OUT decision output for each point in the list sweep table
  • Input protection: internal circuit protection, when a charged capacitor is connected to the unknown terminals. The maximum capacitor voltage can be calculated: Vmax = 1/√C where: Vmax ≤ 200V C is in Farads
  • Memory: 20  instrument setting files can be stored/loaded from the internal non-volatile memory. 40 additional setting files can also be stored/loaded from USB disk (only ST2828)
  • GPIB, RS232C: All instrument control settings, measured values, comparator limits and list sweep tables can communicate with computer or other instruments through GPIB (option) or RS232C.

General Specifications

  • Dimensions: 430 (Width) x 185 (Height) x 490 (Depth) mm
  • Weight: 13 kg
  • Power: 115 / 230 V ± 10 %, 50/60 Hz
  • Power consumption: ≤ 80 VA
  • Temperature / Humidity: 0°C - 40°C, ≤ 90% RH
  • Ambient Temperature: 23°C ± 5°C
  • Warm up Time  ≥ 30 minutes
  • CE conformity, according EN 50 19

Standard accessories (inclusive)

  • 4 terminal Kelvin test clip leads 
  • 4-terminal-test-fixture
  • Gilded shorting plate
  • Power cord
  • Operation manual
  • Certificate of calibration

Options

  • ST26001A - 4-terminal-test-fixture
  • ST26008 SMD test fixture
  • Power amplifier / DC Bias: Increasing AC test signal up to 20 Vrms/0.2 Arms, extend bias voltage up to ±40V DC
  • GPIB interface board and cable
  • Handler/scanner interface board (nine pairs of high/low limits can be input providing 10-bin sorting for L/C/Z. The handler interface provides the interface with an automatic component sorting machine. All signals are optically isolated.
  • ST2818 RS232C control software

  Download user manual ST2818 (PDF 1.100 kB)


SMD component test fixture:
  without  
  Test fixture for contacting SMT Devices, ST26008   + 167,00 EUR
 

from 3.390,00 EUR plus. 19 % Tax
from 4.034,10 EUR incl. 19% TAX
excl.
Shipping time: 1-2 weeks
Print product data sheet 
 


Precision LCR Meter ST2818 Measurement Instrument buy online in Sourcetronic Online Shop.




Parse Time: 0.169s