Hipot Tester's of the HA3600 series have been developed for clearance and creepage distance testing of electrical devices and installations. The design of these can be conducted according VDE 0110 and IEC 384 referrals respectively. For 25 years, Hipot Tester's of this robust class have been used worldwide and are being improved continually. There are special, built-in measurement converters for precise readings of current flow and voltage. The major display readings are reliably readable. These Hipot Tester's fullfil all testing standards for up to 5000V AC. The zero voltage channel will be turned on and off respectively, for optimal protection from overvoltage of the device under test.
Data
- Test Voltage 0-5000 V AC
- Short Circuit Current >200 mA
- Effective range of release current: 0.1 – 100mA
- Hipot transformer with construction work: 500 VA
- Voltage continuously variable from 5% - 105%
- Adjustments of test voltage over a robust control dial
- Release current internally adjustable from 10% - 105%
- Switch able tests:
- test - burn
- Optic and acoustic error message
- Primary Voltage Acquisition
- Secondary leakage current acquisition
- High voltage terminals for testing pistols or adapters.
- Voltage Display Instrument, class 1.5
- Highest Safety (absolutely EN 50191) :
- Key switch preventing unauthorized use - High voltage absolutely potential-free - Two fold isolated transformer and measurement converter - Status indication - Socket X1: For external pilot lamp - Integrated warning buzzer - Insulated sockets - Security activation knob in compliance with VDE0104 - Safety Circuit with forcibly actuated high voltage relays
- Compact 1.4“ 3 HE industrial casing
- Mass: 360 x 330 x 157 mm
- Weight: 14 kg
- Supply : 230 V ± 10 %, 50/60 Hz, max. 400 VA, 6,3 At
- Distortion Factor: <5%
- Storage Temperature + 5° up to +50°
- Operating temperature: +15° up to +40°
- Air humidity: 70% (non-condensing)
- CE-compliant, in accordance with EN 50191
- Hipot Tester in compliance with insulation type IP21
|
Calibration:
|
|
|
without
|
|
|
|
|
MP 01 calibration protocol according ISO 9001
|
|
+ 69,00 EUR |
| |
|
HV Probes:
|
|
|
without
|
|
|
|
|
Set: 2 hvprobes SP02 with 5 m HV-cable
|
|
+ 210,00 EUR |
|
|
Set: 2 hvprobes SP02 with 2 m HV-cable
|
|
+ 142,00 EUR |
| |
|
HV-STOP-chain:
|
|
|
KE 01 PVC stop chain Price/meter
|
|
+ 6,00 EUR |
| |
|
Mains supply Tester:
|
|
|
without
|
|
|
|
|
PW 15 mains supply 115 V (1-phase)
|
|
+ 147,00 EUR |
| |
|
Set-up handle :
|
|
|
without
|
|
|
|
|
AG 38 Set-up handle for 14
|
|
+ 87,00 EUR |
| |
|
Test cage HV Test:
|
|
|
without
|
|
|
|
|
test cage with approved safety relay for direct operation, HB330
|
|
+ 1.496,00 EUR |
| |
|
Test Dummy:
|
|
|
without
|
|
|
|
|
D 2000 Test Dummy for HV test
|
|
+ 208,00 EUR |
| |
|
Warning lamp HV tester:
|
|
|
without
|
|
|
|
|
WL 23 warning lamp set with cable 1.5 m
|
|
+ 115,00 EUR |
| |
|
Warning sign HV test:
|
|
|
without
|
|
|
|
|
WS 01 warning sign
|
|
+ 9,00 EUR |
| |
|